May 25, 2021 <br /> 127 Ft Monopole Tower Structural Analysis CCl BU No 823967 <br /> Project Number 406642, Order 546770, Revision 1 Page 26 <br /> Description Elevation Offset Azimuth E„ EhX Ehz Eh <br /> From Angle <br /> Centroid <br /> ft ft K K K K <br /> RRH4X45(UHIE) <br /> CCISeismic cci tower mounts 116.00 0.00 0.0000 0.02 0.00 0.00 0.02 <br /> (v2.1)Side Arm Mount[SO <br /> 102-3] <br /> CCISeismic alcatel lucent 116.00 0.00 0.0000 0.01 0.00 0.00 0.02 <br /> RRH2X40-07-L <br /> CCISeismic alcatel lucent 116.00 0.00 0.0000 0.01 0.00 0.00 0.02 <br /> RRH2X40-07-L <br /> CCISeismic alcatel lucent 116.00 0.00 0.0000 0.01 0.00 0.00 0.02 <br /> RRH2X40-07-L <br /> CCISeismic cci tower mounts 115.00 0.00 0.0000 0.02 0.00 0.00 0.02 <br /> (v2.1)Side Arm Mount[SO <br /> 102-3] <br /> CCISeismic cci tower mounts 115.00 0.00 0.0000 0.01 0.00 0.00 0.01 <br /> (v2.1)Side Arm Mount[SO <br /> 102-1] <br /> CCISeismic alcatel lucent 115.00 0.00 0.0000 0.01 0.00 0.00 0.02 <br /> RRH2X40-07-L <br /> CCISeismic alcatel lucent 115.00 0.00 0.0000 0.01 0.00 0.00 0.02 <br /> RRH2X40-07-L <br /> CCISeismic alcatel lucent 115.00 0.00 0.0000 0.01 0.00 0.00 0.02 <br /> RRH2X40-07-L <br /> CCISeismic raycap DC6-48- 115.00 0.00 0.0000 0.00 0.00 0.00 0.01 <br /> 60-18-8F <br /> CCISeismic(6)andrew LDF5- 122.00 0.00 0.0000 0.00 0.00 0.00 0.01 <br /> 50A(7/8)From 0 to 127(117ft <br /> to127ft) <br /> CCISeismic(6)andrew LDF5- 112.00 0.00 0.0000 0.00 0.00 0.00 0.01 <br /> 50A(7/8)From 0 to 127(107ft <br /> to117ft) <br /> CCISeismic(6)andrew LDF5- 102.00 0.00 0.0000 0.00 0.00 0.00 0.01 <br /> 50A(7/8)From 0 to 127(97ft <br /> to 107ft) <br /> CCISeismic(6)andrew LDF5- 92.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(87ft <br /> to97ft) <br /> CCISeismic(6)andrew LDF5- 82.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(77ft <br /> to87ft) <br /> CCISeismic(6)andrew LDF5- 72.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(67ft <br /> to77ft) <br /> CCISeismic(6)andrew LDF5- 62.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(57ft <br /> to67ft) <br /> CCISeismic(6)andrew LDF5- 52.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(47ft <br /> to57ft) <br /> CCISeismic(6)andrew LDF5- 42.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(37ft <br /> to47ft) <br /> CCISeismic(6)andrew LDF5- 32.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(27ft <br /> to37ft) <br /> CCISeismic(6)andrew LDF5- 22.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(17ft <br /> to27ft) <br /> CCISeismic(6)andrew LDF5- 12.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(7ft <br /> to17ft) <br /> CCISeismic(6)andrew LDF5- 3.50 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 50A(7/8)From 0 to 127(Oft <br /> to7ft) <br /> CCISeismic(2)nokia HCS 122.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 2.0 Part 2(5/8)From 0 to 127 <br /> (117ft to127ft) <br /> CCISeismic(2)nokia HCS 112.00 0.00 0.0000 0.00 0.00 0.00 0.00 <br /> 2.0 Part 2(5/8)From 0 to 127 <br /> tnxTower Report-version 8.0.9.0 <br /> 2r1IWI) <br />