Laserfiche WebLink
March 08, 2022 <br /> 130 Ft Monopole Tower Structural Analysis CCI BU No 815285 <br /> Project Number 2084453, Order 607190, Revision 1 Page 16 <br /> Description Elevation Offset Azimuth Enz En <br /> From Angle <br /> Centroid <br /> ft ft K K K K <br /> 2(1-7/16)From 0 to 129(100ft <br /> to110ft) <br /> CCISeismic(3)samsung 95.000 0.000 0.000 0.004 0.000 0.000 0.004 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(90ft <br /> to100ft) <br /> CCISeismic(3)samsung 85.000 0.000 0.000 0.004 0.000 0.000 0.004 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(80ft <br /> to90ft) <br /> CCISeismic(3)samsung 75.000 0.000 0.000 0.004 0.000 0.000 0.003 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(70ft <br /> to80ft) <br /> CCISeismic(3)samsung 65.000 0.000 0.000 0.004 0.000 0.000 0.002 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(60ft <br /> to70ft) <br /> CCISeismic(3)samsung 55.000 0.000 0.000 0.004 0.000 0.000 0.002 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(50ft <br /> to60ft) <br /> CCISeismic(3)samsung 45.000 0.000 0.000 0.004 0.000 0.000 0.001 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(40ft <br /> to50ft) <br /> CCISeismic(3)samsung 35.000 0.000 0.000 0.004 0.000 0.000 0.001 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(30ft <br /> to40ft) <br /> CCISeismic(3)samsung 25.000 0.000 0.000 0.004 0.000 0.000 0.000 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(20ft <br /> to30ft) <br /> CCISeismic(3)samsung 15.000 0.000 0.000 0.004 0.000 0.000 0.000 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(10ft <br /> to20ft) <br /> CCISeismic(3)samsung 5.000 0.000 0.000 0.004 0.000 0.000 0.000 <br /> telecommunications TYPE <br /> 2(1-7/16)From 0 to 129(Oft <br /> to1 Oft) <br /> CCISeismic(12)andrew 94.500 0.000 0.000 0.007 0.000 0.000 0.009 <br /> LDFS-50A(7/8)From 0 to 99 <br /> (90ft to99ft) <br /> CCISeismic(12)andrew 85.000 0.000 0.000 0.008 0.000 0.000 0.008 <br /> LDFS-50A(7/8)From 0 to 99 <br /> (80ft to90ft) <br /> CCISeismic(12)andrew 75.000 0.000 0.000 0.008 0.000 0.000 0.006 <br /> LDFS-50A(7/8)From 0 to 99 <br /> (70ft to80ft) <br /> CCISeismic(12)andrew 65.000 0.000 0.000 0.008 0.000 0.000 0.005 <br /> LDF5-50A(7/8)From 0 to 99 <br /> (60ft to70ft) <br /> CCISeismic(12)andrew 55.000 0.000 0.000 0.008 0.000 0.000 0.003 <br /> LDF5-50A(7/8)From 0 to 99 <br /> (50ft to60ft) <br /> CCISeismic(12)andrew 45.000 0.000 0.000 0.008 0.000 0.000 0.002 <br /> LDF5-50A(7/8)From 0 to 99 <br /> (40ft to50ft) <br /> CCISeismic(12)andrew 35.000 0.000 0.000 0.008 0.000 0.000 0.001 <br /> LDF5-50A(7/8)From 0 to 99 <br /> (30ft to40ft) <br /> CCISeismic(12)andrew 25.000 0.000 0.000 0.008 0.000 0.000 0.001 <br /> LDF5-50A(7/8)From 0 to 99 <br /> (20ft to30ft) <br /> CCISeismic(12)andrew 15.000 0.000 0.000 0.008 0.000 0.000 0.000 <br /> LDF5-50A(7/8)From 0 to 99 <br /> tnxTower Report-version 8.1.1.0 - <br />