Laserfiche WebLink
Linear Loads <br /> • <br /> Name Start Height End Height h, w, w,h,k C.,, F,a, F,,, <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 120.00 129.00 124.50 0.0162 251.10 0.0010 0.0070 0.0032 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 110.00 120.00 115.00 0.0180 238.05 0.0009 0.0066 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 100.00 110.00 105.00 0.0180 198.45 0.0008 0.0055 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 90.00 100.00 95.00 0.0180 162.45 0.0006 0.0045 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 80.00 90.00 85.00 0.0180 130.05 0.0005 0.0036 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 70.00 80.00 75.00 0.0180 101.25 0.0004 0.0028 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 60.00 70.00 65.00 0.0180 76.05 0.0003 0.0021 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 50.00 60.00 55.00 0.0180 54.45 0.0002 0.0015 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 40.00 50.00 45.00 0.0180 36.45 0.0001 0.0010 0.0036 <br /> (3)sarnsung telecommunications TYPE 2(1-7/16)From 0 to 129 30.00 40.00 35.00 0.0180 22.05 0.0001 0.0006 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 20.00 30.00 25.00 0.0180 11.25 0.0000 0.0003 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 10.00 20.00 15.00 0.0180 4.05 0.0000 0.0001 0.0036 <br /> (3)samsung telecommunications TYPE 2(1-7/16)From 0 to 129 0.00 10.00 5.00 0.0180 0.45 0.0000 0.0000 0.0036 <br /> (12)andrew LDF5-50A(7/8)From 0 to 99 90.00 99.00 94.50 0.0356 318.27 0.0012 0.0088 0.0071 <br /> (12)andrew LDF5-50A(7/8)From 0 to 99 80.00 90.00 85.00 0.0396 286.11 0.0011 0.0079 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 99 70.00 80.00 75.00 0.0396 222.75 0.0009 0.0062 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 99 60.00 70.00 65.00 0.0396 167.31 0.0007 0.0046 0.0079 <br /> (12)andrew LDFS-50A(7/8)From 0 to 99 50.00 60.00 55.00 0.0396 119.79 0.0005 0.0033 0.0079 <br /> (12)andrew LDF5-506(7/8)From 0 to 99 40.00 50.00 45.00 0.0396 80.19 0.0003 0.0022 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 99 30.00 40.00 35.00 0.0396 48.51 0.0002 0.0013 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 99 20.00 30.00 25.00 0.0396 24.75 0.0001 0.0007 0.0079 <br /> (12)andrew LDFS-50A(7/8)From 0 to 99 10.00 20.00 15.00 0.0396 8.91 0.0000 0.0002 0.0079 <br /> (12)andrew LDFS-50A(7/8)From 0 to 99 0.00 10.00 5.00 0.0396 0.99 0.0000 0.0000 0.0079 <br /> (6)andrew 19F7-50A(1-5/8)From 0 to 99 90.00 99.00 94.50 0.0443 395.43 0.0015 0.0110 0.0089 <br /> (6)andrew LDF7-50A(1-5/8)From 0 to 99 80.00 90.00 85.00 0.0492 355.47 0.0014 0.0099 0.0098 <br /> (6)andrew LDF7-S0A(1-5/8)From Ito 99 70.00 80.00 75.00 0.0492 276.75 0.0011 0.0077 0.0098 <br /> (6)andrew LDF7-50A(1-5/8)From 0 to 99 60.00 70.00 65.00 0.0492 207.87 0.0008 0.0058 0.0098 <br /> (6)andrew LDF7-50A(1-5/8)From 0 to 99 50.00 60.00 55.00 0.0492 148.83 0.0006 0.0041 0.0098 <br /> (6)andrew LDF7-50A(1-5/8)From 0 to 99 40.00 50.00 45.00 0.0492 99.63 0.0004 0.0028 0.0098 <br /> (6)andrew LDF7-506(1-5/8)From 0 to 99 30.00 40.00 35.00 0.0492 60.27 0.0002 0.0017 0.0098 <br /> (6)andrew LDF7-50A(1-5/8)From 0 to 99 20.00 30.00 25.00 0.0492 30.75 0.0001 0.0009 0.0098 <br /> (6)andrew LDF7-506(1-5/8)From 0 to 99 10.00 20.00 15.00 0.0492 11.07 0.0000 0.0003 0.0098 <br /> (6)andrew LDF7-50A(1-5/8)From 0 to 99 0.00 10.00 5.00 0.0492 1.23 0.0000 0.0000 0.0098 <br /> (4)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 90.00 99.00 94.50 0.0210 187.75 0.0007 0.0052 0.0042 <br /> (4)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 80.00 90.00 85.00 0.0234 168.78 0.0007 0.0047 0.0047 <br /> (4)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 70.00 80.00 75,00 0.0234 131.40 0.0005 0.0036 0.0047 <br /> (4)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 60.00 70.00 65.00 0.0234 98.70 0.0004 0.0027 0.0047 <br /> (4)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 50.00 60.00 55.00 0.0234 70.66 0.0003 0.0020 0.0047 <br /> (4)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 40.00 50.00 45.00 0.0234 47.30 0.0002 0.0013 0.0047 <br /> (4)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 30.00 40.00 35.00 0.0234 28.62 0.0001 0.0008 0.0047 <br /> (4)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 20.00 30.00 25.00 0.0234 14.60 0.0001 0.0004 0.0047 <br /> (4)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 10.00 20.00 15.00 0.0234 5.26 0.0000 0.0001 0.0047 <br /> (4)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 0.00 10.00 5.00 0.0234 0.58 0.0000 0.0000 0.0047 <br /> (2)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 90.00 99.00 94.50 0.0105 93.87 0.0004 0.0026 0.0021 <br /> (2)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 80.00 90.00 85.00 0.0117 84.39 0.0003 0.0023 0.0023 <br /> (2)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 70.00 80.00 75.00 0.0117 65.70 0.0003 0.0018 0.0023 <br /> (2)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 60.00 70.00 65.00 0.0117 49.35 0.0002 0.0014 0.0023 <br /> (2)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 50.00 60.00 55.00 0.0117 35.33 0.0001 0.0010 0.0023 <br /> (2)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 40.00 50.00 45.00 0.0117 23.65 0.0001 0.0007 0.0023 <br /> (2)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 30.00 40.00 35.00 0.0117 14.31 0.0001 0.0004 0.0023 <br /> (2)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 20.00 30.00 25.00 0.0117 7.30 0.0000 0.0002 0.0023 <br /> (2)rosenberger leoni WR-VG86ST-BRD(3/4)From 0 to 99 10.00 20.00 15.00 0.0117 2.63 0.0000 0.0001 0.0023 <br /> (2)rosenberger leoni WR-VG865T-BRD(3/4)From 0 to 99 0.00 10.00 5.00 0.0117 0.29 0.0000 0.0000 0.0023 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 90.00 99.00 94.50 0.0756 675.13 0.0026 0.0187 0.0151 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 80.00 90.00 85.00 0.0840 606.90 0.0024 0.0168 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 70.00 80.00 75.00 0.0840 472.50 0.0018 0.0131 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 60.00 70.00 65.00 0.0840 354.90 0.0014 0.0098 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 50.00 60.00 55.00 0.0840 254.10 0.0010 0.0070 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 40.00 50.00 45.00 0.0840 170.10 0.0007 0.0047 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 30.00 40.00 35.00 0.0840 102.90 0.0004 0.0029 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 20.00 30.00 25.00 0.0840 52.50 0.0002 0.0015 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 10.00 20.00 15.00 0.0840 18.90 0.0001 0.0005 0.0168 <br /> (3)miscl 2"Rigid Conduit From 0 to 99 0.00 10.00 5.00 0.0840 2.10 0.0000 0.0001 0.0168 <br /> (12)andrew LDFS-S0A(7/8)From 0 to 86 80.00 86.00 83.00 0.0238 163.68 0.0006 0.0045 0.0048 <br /> (12)andrew LDFS-50A(7/8)From 0 to 86 70.00 80.00 75,00 0.0396 222.75 0.0009 0.0062 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 86 60.00 70.00 65.00 0.0396 167.31 0.0007 0.0046 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 86 50.00 60.00 55.00 0.0396 119.79 0.0005 0.0033 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 86 40.00 50.00 45.00 0.0396 80.19 0.0003 0.0022 0.0079 <br /> (12)andrew LDFS-50A(7/8)From 0 to 86 30.00 40.00 35.00 0.0396 48.51 0.0002 0.0013 0.0079 <br /> (12)andrew LDFS-50A(7/8)From 0 to 86 20.00 30.00 25.00 0.0396 24.75 0.0001 0.0007 0.0079 <br /> (12)andrew L12F5-50A(7/8)From 0 to 86 10.00 20.00 15.00 0.0396 8.91 0.0000 0.0002 0.0079 <br /> (12)andrew LDF5-50A(7/8)From 0 to 86 0.00 10.00 5.00 0.0396 0.99 0.0000 0.0000 0.0079 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 80.00 86.00 83.00 0.0205 141.36 0.0005 0.0039 0.0041 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 70.00 80.00 75.00 0.0342 192.38 0.0007 0.0053 0.0068 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 60.00 70.00 65.00 0.0342 144.50 0.0006 0.0040 0,0068 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 50.00 60.00 55.00 0.0342 103.46 0.0004 0.0029 0.0068 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 40.00 50.00 45.00 0.0342 69.26 0.0003 0.0019 0.0068 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 30.00 40.00 35.00 0.0342 41.90 0.0002 0.0012 0.0068 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 20.00 30.00 25.00 0.0342 21.38 0.0001 0.0006 0.0068 <br /> (2)nokia HCS 2.0 Part 3(1-1/2)From 0 to 86 10.00 20.00 15.00 0.0342 7.70 0.0000 0.0002 0.0068 <br /> CCISeismic 3.3.9 Page 6 Analysis Date: 3/8/2022 <br />