REVISIONS <br /> WOOD NAILER SECUREMENT CRITERIA FASTENERS THROUGH STEEL ANGLE 0 <br /> REQUIREMENTS BASED ON FACTORY MUTUAL LOSS PREVENTION DATA BULLETIN WITH MODIFICATIONS 2"X 6"TREATED ANCHOR BOLT DIAMETER), T APART 0 <br /> EXISTING OR NEWW STAINLESS STEEL 0 <br /> WOOD NAILER INSULATION 2"X 6"TREATED WOOD NAILER 3 <br /> ONE OF THE MOST OFTEN OVERLOOKED DETAILS ON A ROOFING SYSTEM IS THE ATTACHMENT METHOD FOR WOOD NAILERS AT THE PERIMETER <br /> OF THE ROOF. FACTORY MUTUAL(FM)PUBLISHES DESIGN RECOMMENDATIONS FOR THE ATTACHMENT OF WOOD NAILERS TO VARIOUS ANCHOR BOLT 48"O.C. <br /> SUBSTRATES AND FOR THE ATTACHMENT OF PERIMETER FLASHING DETAILS TO WOOD NAILERS.THIS INFORMATION IS CONTAINED IN FACTORY <br /> MUTUAL'S LOSS PREVENTION DATA BULLETIN 1-49. IN ACCORDANCE WITH THAT BULLETIN,THE INFORMATION LISTED BELOW SHOULD BE <br /> REFERENCED WHEN SELECTING AN APPROPRIATE PERIMETER ATTACHMENT METHOD. <br /> � I I ROOF DECK <br /> GENERAL CRITERIA j j MASONRY <br /> WALL _ <br /> • WOOD NAILERS THAT ARE ANCHORED TO STEEL,WOOD OF MASONRY DECKING SHOULD NOT BE LESS THAN 2"X 6"NOMINAL I I - <br /> (MINIMUM 1-1/2"X 5-1/2"). <br /> • WOOD NAILERS SHOULD BE DOUGLAS FIR,SOUTHERN YELLOW PINE OR OF WOOD HAVING SIMILAR DECAY RESISTANCE PROPERTIES. s <br /> u a <br /> s �A <br /> ATTACHMENT TO MASONRY WALLS • 1/2"ANCHOR BOLTS SPACED 48"ON CENTER <br /> WHEN FASTENING TO A MASONRY WALL,A 1/2 INCH BOLT IS PLACED 48 INCHES ON CENTER AT AN 8 INCH MINIMUM DEPTH(12 INCHES • 3/8"ANCHOR BOLTS SPACED 32"ON CENTER V <br /> MINIMUM WHEN MASONRY WALLS ARE COMPOSED OF LIGHTWEIGHT AGGREGATE OR CINDER)AS SHOWN IN FIGURE 1.EACH ANCHOR • MINIMUM 8"PENETRATION(MINIMUM 12"INTO LIGHTWEIGHT e O <br /> BOLT IS POSITIONED(STAGGERED IF THE WOOD NAILER IS WIDER THAN 6 INCHES)IN A BLOCK CORE OR AIR SPACE AND TIGHTLY FILLED AGGREGATE OR CINDER) F <br /> WITH CONCRETE TO THE DEPTH OF THE BOLT. <br /> • BLOCK CORE OR AIR SPACE TIGHTLY FILLED WITH CONCRETE • 3/4"ANCHOR BOTS SPACED 48"ON CENTER O <br /> 1-60: CONCRETE FILL AT FASTENERS FIGURE 1 • AT 8'-0"CORNERS: a <br /> NOTE: PLASTIC PARTS MUST NOT BE USED WITH MASONRY ANCHORS 1-90: CONCRETE FILL ENTIRE TOP COURSE FASTENING DOUBLED(24"MAX.) <br /> FIGURE 4 <br /> a <br /> ATTACHMENT TO STEEL AND WOOD DECKING �� <br /> FACTORY MUTUAL HAS SPECIFIC REQUIREMENTS CONCERNING FILLING OF CORES OR VOIDS IN THE TOP COURSE OF CINDER BLOCKS a <br /> EXISTING SCREWS OR NEW STAINLESS STEEL EXISTING SCREWS OR NEW STAINLESS STEEL SCREWS <br /> SCREWS AND WASHERS(2 ROWS STAGGERED) AND WASHERS(2 ROWS STAGGERED)PER FIGURE 2 m <br /> FOR EXAMPLE: L <br /> PROJECTS LOCATED IN ZONE 2(FM 1-90 SECUREMENT)-FILL THE ENTIRE TOP COURSE. g O z <br /> PROJECTS LOCATED IN ZONE 1(FM 1-60 SECUREMENT)-FILL ONLY REQUIRED WHERE ANCHOR BOLTS ARE POSITIONED(48 INCHES ON c <br /> CENTER IN THE FIELD,24 INCHES ON CENTER AT ROOF CORNERS) <br /> AT OUTSIDE CORNERS,THE FASTENING DENSITY MUST BE INCREASED WITHIN THE FIRST 8 FEET IN EACH DIRECTION BY POSITIONING s O w <br /> ANCHOR BOLTS 24 INCHES ON CENTER 3 o 0 II <br /> AN ALTERNATE METHOD MAY BE USED BY INSTALLING 3/8 INCH DIAMETER ANCHOR BOLTS SPACED 32 INCHES APART. FOR OUTSIDE <br /> CORNERS,BOLTS ARE FASTENED 16 INCHES APART,8 FEET FROM EACH SIDE OF THE CORNER. IF ADDITIONAL WOOD NAILERS ARE m 0 N <br /> NEEDED,REFER TO FIGURE 5 FOR ATTACHMENT OF ADDITIONAL WOOD NAILERS. `rr^J <br /> U N O <br /> ATTACHMENT TO STEEL AND WOOD DECKING 3 <br /> PENETRATION OF THE FASTENERS SHOULD BE TO THE TOP FLUTES ONLY.THE FASTENERS MUST BE STAGGERED AS SHOWN IN • WOOD NAILERS ATTACHED WITH 2 ROWS OF NO.10 STAINLESS STEEL SCREWS m Z <br /> FIGURE 2 • SPACING OF FASTENERS IN EACH ROW SHALL NOT EXCEED 24 INCHES • SECURE ADDITIONAL NAILERS WITH 2 ROWS OF STAINLESS STEEL NAILS OR LAG Q <br /> SCREWS a Z <br /> 8' <br /> CAUTION:ATTENTION SHOULD BE PAID TO THE FACTORY MUTUAL REQUIREMENT WHICH CALLS FOR GALVANIZED STEEL WASHERS <br /> AT CORNERS,FASTENERS DOUBLED(MAXIMUM 12"ON CENTER IN EACH ROW) SPACING OF FASTENERS IN EACH ROW 24"MAXIMUM <br /> 5/g" <br /> (MINIMUM 5/8 INCH OUTSIDE DIAMETER)TO BE USED IN CONJUNCTION WITH GALVANIZED SCREWS. THIS REQUIREMENT IS NOT • PROVIDE STAINLESS STEEL WASHERS UNDER SCREW HEADS OR PANCAKE • AT 8-0"CORNERS,FASTENING DOUBLED(12"O.C.MAXIMUM) hi;�' <br /> RECOGNIZED IN MOST CASES AND MOST OFTEN FORGOTTEN. SCREWS MINIMUM FASTENER PENETRATION INTO BOTTOM NAILER 1%4" <br /> THE STAGGERED FASTENING PATTERN SHOULD BE INCREASED WITHIN 8 FEET FROM THE OUTSIDE CORNERS AS SHOWN IN FIGURE 3 <br /> s <br /> M <br /> FIGURE 5 N <br /> FIGURE 2 e <br /> IF THE PERIMETER NAILER IS TO BE SECURED TO A STEEL ANGLE,ANCHOR BOLTS MUST BE POSITIONED AT 48 INCH CENTERS AS SHOWN g <br /> IN FIGURE 4. C) <br /> ON WOOD DECKS,THE STAGGERED FASTENING PATTERN WITH GALVANIZED STEEL SCREWS SHOULD BE UTILIZED AS SHOWN IN FIGURE 2 <br /> ROOF AREA A v; w' y <br /> w a3 <br /> CO <br /> ATTACHMENT OF ADDITIONAL WOOD NAILERS FASTENING ENHANCEMENT AT 8'-0"CORNERS Roof Area Dimensions(feet): 500x220 w <br /> WHEN ADDITIONAL WOOD NAILERS ARE REQUIRED,THEY MUST BE ATTACHED WITH GALVANIZED NAILS OR LAG SCREWS THAT Mean Roof Height(feet): 25.0 J •y <br /> PENETRATE INTO THE BOTTOM NAILER AT 1-1/4 INCHES USING A STAGGERED FASTENING PATTERN IN TWO ROWS AT 24 INCHES APART Roof Slope: Flat:11/2:12 or less n V O <br /> AS SHOWN IN FIGURE 5. Parapet(s)(minimum 36 inches high): Yes <br /> Building Configuration Enclosed 8 Q C'4 W <br /> THE INCREASED FASTENING DENSITY WITHIN 8 FEET FROM THE OUTSIDE CORNERS IS STILL REQUIRED AND MUST COMPLY WITH FIGURE 3 2,-0. Exposure: B a <br /> Risk Category: II - <br /> Basic Wind Speed(three-second peak gust, 100 from ASCE 7-16,Figure 26.5-1B Basic Wind Speed <br /> EVEN THOUGH NOT EMPHASIZED IN THE BULLETIN,CONTRACTORS SHOULD EXAMINE OR QUESTION EXISTING CONDITIONS TO DETERMINE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o mph): - <br /> IF EXISTING WOOD NAILERS ARE ATTACHED IN COMPLIANCE WITH THE ABOVE CRITERIA. IF NOT,EXISTING WOOD NAILERS SHOULD BE Roof Deck Type: Wood Roof Covering Type: TPO <br /> 9 <br /> REFASTENED USING ONE OF THESE OPTIONS AND ADDITIONAL WOOD NAILERS MUST BE SECURED FOLLOWING FIGURE 5. 4 � o § <br /> 6' X 1W. <br /> Graphically,the strength design values are dipicted as follows: <br /> WOOD NAILERS PLAY A MAJOR ROLE IN THE PERFORMANCE OF THE ROOFING SYSTEM AND CONTRIBUTE TO THE WIND UPLIFT RESISTANCE 0 2"X 6"TREATED <br /> OF THE ROOF EDGE WHICH IS THE FIRST LINE OF DEFENSE DURING WINDSTORMS. IT IS IMPORTANT TO COMPLY WITH THE ABOVE 1'-0° WOOD NAILER 3 <br /> REQUIREMENTS AND PERIODICALLY CHECK VARIOUS UPDATES PUBLISHED BY FACTORY MUTUAL NOT ONLY FOR THE ATTACHMENT OF E <br /> WOOD NAILERS,BUT ALSO FOR THE SECUREMENT OF METAL EDGING:ESPECIALLY THOSE WHICH ARE SHOP FABRICATED. <br /> City of Everett Permit Review Q <br /> FASTENERS SPACED 24" O.C. OUTSIDE CORNER AREA 2 � <br /> 2 � 3 EVERETT Status: Reviewed for Permit fr W <br /> 3 0� ' 04/30/2024 11:52:29 AM <br /> h <br /> o"a o• o. .�, (3� <br /> J <br /> O O o z <br /> O O Zone I'm 14.7 pounds per square foot W <br /> 3 Zone 1= 25.5 pounds per square foot ULJ W <br /> D• Zone 2= 33.6 pounds per square foot co Q <br /> Zone 3= 45.8 pounds per square foot <br /> FIGURE 3 JOB NO: 70540 <br /> C7: 10.0 feet DATE: 11/15/23 <br /> Zonel' 14.7 pounds per square foot h: 25.0 feet DRAWN: JS <br /> Zonel 25.5 pounds per square foot CKD BY: JT <br /> Zone2 33.6 pounds per square foot 0.2h: 5.0 feet FILENAME:Everett 1 <br /> Zone3 45.8 pounds per square foot 0.6h: 15.0 feet SHEETSIZE: 24"x36" <br /> SHEET 7 of 8 <br /> R3.0 <br /> PLOT DATE:November30,20238:01 AM G:\FMS-Pmj..S(T-Serbs)-Cyb.rC AWulsltlon Projects\70540-FY24SeaNe M,r A05_W,NNFolder,CAD\70540Prd ,,FY24Everelll_Pl,,,,,d De,,I,.dw <br />