My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9914 18TH AVE W E 2025-03-24
>
Address Records
>
18TH AVE W
>
9914
>
9914 18TH AVE W E 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:58:27 AM
Creation date
2/28/2025 10:10:45 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9914
Unit
E
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rough-In/Cover Inspection <br /> Head Placement and Piping: <br /> PASS FAIL N/A <br /> 1. Approved Plans-Approved plans on site?And all work completed per plans? ❑ ❑ ❑ <br /> 2. Visual Inspection -All piping and components, including sprinkler heads, hangers, ❑ ❑ ❑ <br /> valves, and gauges are required to be in place and shall be exposed for visual <br /> inspection. If insulation is to be used for freeze protection, this shall be in place <br /> and fastened, and with the approval of the inspector, is permitted to cover the <br /> necessary exposed pipe. <br /> 3. Head Placement-Verify proper placement of sprinkler heads and piping to ensure ❑ ❑ ❑ <br /> installation is according to the approved plans and/or the designed spacing of the <br /> heads. (Revised drawings should not be required for minor field changes.) <br /> 4. Compatibility-When work with CPVC special consideration is necessary when in ❑ ❑ ❑ <br /> contact with other materials or chemicals. (See manufacturer's guidance on <br /> installation and compatible materials.) <br /> 5. Sprinkler Cabinets-All sprinkler riser assemblies shall be located in a wall, ❑ ❑ ❑ <br /> cabinet, or other enclosure (with a minimum twelve inch (12")wide by thirty-six <br /> inch (36") high access door), unless otherwise approved by the fire code official. <br /> (See Diagram) <br /> 6. Warning Sign -A warning sign,with minimum % in. (6 mm) letters, shall be affixed ❑ ❑ ❑ <br /> adjacent to the main shutoff valve and shall state the following: <br /> WARNING: The water system for this home supplies fire sprinklers that require <br /> certain flows and pressures to fight afire. Devices that restrict the flow or decrease <br /> the pressure or automatically shut off the water to the fire sprinkler system, such <br /> as water softeners,filtration systems, and automatic shutoff valves, shall not be <br /> added to this system without a review of the fire sprinkler system by a fire <br /> protection specialist. Do not remove this sign. <br /> 7. Shut Off Valve-A single control valve arranged to shut off both the domestic ❑ ❑ ❑ <br /> system and the sprinkler system shall be installed. See Passive-purge/Flow <br /> Through Riser Detail below. <br /> 8. Pressure Gauge& Drain -All systems shall be provided with a pressure gauge and ❑ ❑ ❑ <br /> a 1/2" ball valve system drain to outside. <br /> 9. Connections to Toilets-All flow through systems shall be provide with a minimum ❑ ❑ ❑ <br /> of a 1/2" line to connect to a minimum of 2 toilets, at least one toilet per floor. <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-7 4.20.2020 I Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.