Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> Woodinville,WA 98072-4436 <br /> Phone:425-814-8448 <br /> E NGI NEERIl\G Fax:425-821-2120 <br /> Benton Square TH Revision Date: 1/11/2021 <br /> Unit Type 'C' <br /> Redundancy,p 1.0 (Section 12.3.4) <br /> Design Base Shear <br /> S ms = F e S s (Eq. 11.4-1) S m, = F S, (Eq. 11.4-2) <br /> = 1.42 = 0.89 <br /> S Ds = S/S nos (Eq. 11.4-3) S D t= %S M, (Eq. 11.4-4) <br /> = 0.95 = 0.60 <br /> Seismic Design Category: Structure Period and Weight: <br /> Short Period-- D <br /> 1-Second Period-- D Ct = 0.020 Table 12.8-2 <br /> x = 0.75 <br /> Building Height(Mean Roof),h„ = 32 ft <br /> Approximate Fundamental Period, Ta = Ct (h„)" (Eq. 12.8-7) <br /> T= Ta = 0.27 <br /> T L = 6 (Figs. 22-14 thru 22-17) <br /> Calculated design base shear., <br /> V= CS W (Eq. 12.8-1) <br /> SDS_ <br /> CS = (Te <br /> R) (Eq. 12.8-2) <br /> CS = 0.15 <br /> The total design base shear need not exceed., <br /> (Eq. 12.8-3) (Eq. 12.8-4) <br /> for T T C — SDI SD1TL <br /> L S — T(Rl for T> TL CS = T2(TR} <br /> C5 = 0.344 Cs = 7.53 <br /> CS = 0.34 T<_TL <br /> C S = 0.51 1.5 times Cs in accordance with 11.4.8 <br /> The total design base shear shall not be less than: <br /> Cs = 0.044SDs/e ?0.01 (Eq. 12.8-5) <br /> CS = 0.04 <br /> nor where S t >_ 0.6g. <br /> Cs = 0.5S,/(Rile) (Eq. 12.8-6) <br /> CS = 0.00 <br /> CS = 0.15 <br /> V= 0.15W <br /> Date:5/30/2023 <br /> Page: L1.3 r` <br />