My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11625 AIRPORT RD SONRISE CHRISTIAN CENTER 2025-04-11
>
Address Records
>
AIRPORT RD
>
11625
>
SONRISE CHRISTIAN CENTER
>
11625 AIRPORT RD SONRISE CHRISTIAN CENTER 2025-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2025 9:58:33 AM
Creation date
3/3/2025 7:59:47 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11625
Tenant Name
SONRISE CHRISTIAN CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � � 11 _ ♦ , <br /> Table 12.2B Cut Thread or Rolled Thread Wood Screw Reference Withdrawal Design Values, Wl <br /> Tabulated withdrawal design values,W,are in pounds per inch of thread penetration into side grain of wood <br /> member(see 12.2.2.1). <br /> Specific Wood Screw Number <br /> Gravity, 6 7 8 9 10 12 14 16 18 20 24 <br /> G2 <br /> 0.73 209 229 249 268 288 327 367 406 446 485 564 <br /> 0.71 198 216 235 254 272 310 347 384 421 459 533 <br /> 0.68 181 199 216 233 250 284 318 352 387 421 489 <br /> 0.67 176 193 209 226 243 276 309 342 375 409 475 <br /> 0.58 132 144 157 169 182 207 232 256 281 306 356 <br /> 0.55 119 130 141 152 163 186 208 231 253 275 320 <br /> 0.51 102 112 121 131 141 160 179 198 217 237 275 <br /> 0.50 98 107 117 126 135 154 172 191 209 228 264 <br /> 0.49 94 103 112 121 130 147 165 183 201 219 254 <br /> 0.47 87 95 103 111 119 136 152 168 185 201 234 <br /> 0.46 83 91 99 107 114 130 146 161 177 193 224 <br /> 0.44 76 83 90 97 105 119 133 148 162 176 205 <br /> 0.43 73 79 86 93 100 114 127 141 155 168 196 <br /> 0.42 69 76 82 89 95 108 121 134 147 161 187 <br /> 0.41 66 72 78 85 91 103 116 128 141 153 178 <br /> 0.40 63 69 75 81 86 98 110 122 134 146 169 <br /> 0.39 60 65 71 77 82 93 105 116 127 138 161 <br /> 0.38 57 62 67 73 78 89 99 110 121 131 153 <br /> 0.37 54 59 64 69 74 84 94 104 114 125 145 <br /> 0.36 51 56 60 65 70 80 89 99 108 118 137 <br /> 0.35 48 53 57 62 66 75 84 93 102 111 130 <br /> 0.31 38 41 45 48 52 59 66 73 80 87 102 <br /> 1. Tabulated withdrawal design values,W,for wood screw connections shall be multiplied by all applicable adjustment factors(see Table 11.3.1). <br /> 2. Specific gravity,G,shall be determined in accordance with Table 12.3.3A. <br /> (b) For Roof Sheathing Ring Shank nails (Appen- 12.2.3.4 Nails and spikes shall not be loaded in <br /> dix Table L6) or Post-Frame Ring Shank nails (Appen- withdrawal from end-grain of laminations in cross- <br /> dix Table L5) that are uncoated carbon steel, reference laminated timber(Ceg 0.0). <br /> withdrawal design values determined from Table 12.2E 12.2.4 Drift Bolts and Drift Pins <br /> or Equation 12.2-5 shall be permitted to be multiplied <br /> by 1.25. Reference withdrawal design values, W, for con- <br /> (c) For calculation of the fastener reference with- nections using drift bolt and drift pin connections shall <br /> drawal design value in pounds, the unit reference with- be determined in accordance with 11.1.1.3. <br /> drawal design value in lbs/in. of ring shank penetration <br /> from 12.2.3.2a or 12.2.3.2b shall be multiplied by the 12.2.5 Fastener Head Pull-Through <br /> length of ring shank penetration, pt, into the wood <br /> member. 12.2.5.1 For fasteners with round heads, the refer- <br /> (d) For other deformed shank nails, reference with- ence pull-through design value, WH, in pounds for <br /> drawal design values shall be permitted to be calculated wood side members shall be determined from Table <br /> in accordance with 12.2.3.1. 12.2F or Equation 12.2-6, within the range of fastener <br /> 12.2.3.3 Nails and spikes shall not be loaded in head diameters, DH, and net side member thicknesses, <br /> withdrawal from end grain of wood Ce =0.0 . t„S, given in Table 12.2F. Reference pull-through design <br /> values, WH, shall be multiplied by all applicable ad- <br /> justment factors (see Table 11.3.1) to obtain adjusted <br /> pull-through design values,W . <br /> Copyright©American Wood Council.Downloaded/printed pursuant to License Agreement.No reproduction or transfer authorized. <br /> AMERICAN WOOD COUNCIL <br /> 11 of1_6) <br />
The URL can be used to link to this page
Your browser does not support the video tag.