Laserfiche WebLink
BC - BEAM TO COLUMN - continued... <br /> AISC <br /> Web Local Crippling (J10-5b) <br /> = 2.00 <br /> Demand Rn Rn/U <br /> kip kip kip Stress <br /> 37.70 231.1 115.5 32.6% OK <br /> AISC <br /> Web Sidesway Buckling Does not apply for cont. braced beams (J10-6) <br /> = 1.76 <br /> Demand Rn Rn/f) <br /> kip kip kip Stress <br /> 37.70 N/A N/A N/A N/A <br /> AISC <br /> Web Compression Buckling (J10-8) <br /> �= 1.67 <br /> Demand Rn Rn/fU <br /> kip kip kip Stress <br /> 37.70 177.0 106.0 35.6% OK <br /> Summary Rn/fU <br /> Flange Local Bending: 108.1 34.9% Min 106.0 <br /> Web Local Yielding: 185.6 20.3% Demand 37.7 <br /> Web Local Crippling: 115.5 32.6% <br /> Web Sidesway Buckling: <br /> Web Compression Buckling: 106.0 35.6% <br /> Transverse stiffeners are NOT REQUIRED <br /> Design Stiffeners AISC <br /> The following section does not apply if the above criteria are all met (J4-6) <br /> Fy Fu t b h lb tw K-cut <br /> ksi ksi in in in in in in <br /> 36 58 0.5 4.9775 28.28 3.9775 0.545 1 <br /> A plates web A r Kh/r <br /> in"4 in"2 in"2 in"2 in _ <br /> 48.3 4.98 3.56 8.54 5.66 5.00 OK <br /> = 1.67 <br /> Demand Pn Pn/fU <br /> kip kip kip Stress <br /> 37.7 179.2 107.3 35.1% OK <br /> • <br />