Laserfiche WebLink
A This Is a beta release of the new ATC Hazards by Location website.Please COrnact us with feedback. <br /> 0 The ATC Hazards by Location website will not be updated to support ASCE 7-22.Find out why, <br /> ATCHazards by Location <br /> Search Information / Oak Harbor <br /> Address: 1321 Colby Ave,Everett,WA 98201,USA 139 ft <br /> on Angeles ":41. <br /> Coordinates: 48.0001786,-122.2078756 Seguinf <br /> 3azer a'Inq�O'rr,,, <br /> Elevation: 139ft 'Whidbey <br /> Is-and o <br /> Timestamp: 2023-02-07T21:19:05.242Z U <br /> Hazard Type: Seismic <br /> Reference Document: ASCE7-16 Seattle OReiMap data©2023 Google.Reports map error <br /> Risk Category: IV <br /> Site Class: D-default <br /> Basic Parameters <br /> Name Value Description <br /> SS 1.211 MCER ground motion(period=0.2s) <br /> Si 0.431 MCER ground motion(period=1.0s) <br /> SMS 1.453 Site-modified spectral acceleration value <br /> SM1 *null Site-modified spectral acceleration value <br /> SOS 0.969 Numeric seismic design value at 0.2s SA <br /> SD1 'null Numeric seismic design value at 1.Os SA <br /> *See Section 11.4.8 <br /> Additional Information <br /> Name Value Description <br /> SDC 'null Seismic design category <br /> Fa 1.2 Site amplification factor at 0.2s <br /> Fn *null Site amplification factor at 1.Os <br /> CRs 0.905 Coefficient of risk(0.2s) <br /> CR1 0.893 Coefficient of risk(1.0s) <br /> PGA 0.519 MCEO peak ground acceleration <br /> FpGA 1.2 Site amplification factor at PGA <br /> PGAM 0.623 Site modified peak ground acceleration <br /> TL 6 Long-period transition period(s) <br /> SsRT 1.211 Probabilistic risk-targeted ground motion(0.2s) <br /> SsUH 1.338 Factored uniform-hazard spectral acceleration(2%probability of <br /> exceedance in 50 years) <br /> SsD 3.176 Factored deterministic acceleration value(0.2s) <br /> S1 RT 0.431 Probabilistic risk-targeted ground motion(1.Os) <br /> S1UH 0.482 Factored uniform-hazard spectral acceleration(2%probability of <br /> exceedance in 50 years) <br /> S1 D 1.193 Factored deterministic acceleration value(1.Os) <br /> PGAd 1.074 Factored deterministic acceleration value(PGA) <br /> See Section 11.4.8 <br /> The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any <br /> output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. <br /> Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22.Findptttwhy. <br /> Disclaimer <br />