My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • 10 of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> HVAC CONTROLS <br /> NA C403.4.1 Thermostatic controls Indicate locations of thermostatic and <br /> (thermostats and humidity control devices and the zones they <br /> humidistats) serve on plans,including perimeter system <br /> zones <br /> Where adjacent(neighboring)zones are <br /> controlled by separate thermostats(including <br /> perimeter systems used to offset heat gain or <br /> loss),and are connected by permanent <br /> openings>10%of either zone sf area, <br /> indicate controls configured to prevent <br /> adjacent zones from operating in conflicting <br /> modes(one in heat,other in cool);applies to <br /> adjacent perimeter zones,adjacent <br /> nonperimeter zones,and adjacent perimeter <br /> and nonperimeter zones <br /> If applying Exception 2 to nonperimeter zones <br /> adjacent to perimeter zones,indicate that <br /> setpoints and deadband settings in these zones <br /> are coordinated so cooling in a nonperimeter <br /> zone does not occur until the temperature in <br /> that zone is 5'F higher than the adjacent <br /> perimeter zone temperature in heating <br /> NA If applying Exception 3 for DOAS,indicate <br /> supply air temperature heating setpoint is<_ <br /> 65°F and cooling setpoint is>_72°F,or <br /> method of supply air temperature reset <br /> NA C403.4.1.1 Heat pump Indicate staged heating operation with <br /> supplementary heat compression as the first stage of heating and <br /> supplemental heating controlled with outdoor <br /> lock-out temperature set to 40°F or less <br /> C403.4.1.2 Deadband Indicate zone thermostatic controls configured <br /> with 5°F minimum deadband for systems that <br /> control both heating and cooling <br /> C403.4.1.3 Setpoint overlap If separate heating and cooling thermostatic <br /> restriction control devices are used to serve a zone, <br /> (thermostats) indicate locations of both thermostatic control <br /> devices and the zone they serve on plans <br /> Indicate a limit switch,mechanical stop or <br /> DDC control with programming to prevent <br /> simultaneous hearing and cooling <br /> NA C403.4.1.4 Heated or cooled Indicate thermostatic controls within heating <br /> vestibules or cooled vestibules with a heating setpoint<_ <br /> 60°F and cooling setpoint>_85°F;indicate <br /> controls are configured to turn off heating <br /> when outdoor temperature is>45°F;or note <br /> exception applied <br /> NA C403.4.1.4 Heated air curtains Indicate controls are configured to turn off air <br /> curtain heating when outdoor temperature is> <br /> 45°F <br /> Page 10125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.