My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • • of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.4.3.2 Two-pipe changeover Indicate changeover deadband is> l5°F <br /> systems outdoor air temperature;indicate controls are <br /> configured so that heating/cooling modes are <br /> active for at minimum 4 hours before <br /> changeover and that the delta between heating <br /> /cooling supply temperatures at changeover <br /> point is <br /> C403.4.1.5 Heating water For boilers that provide building heating via <br /> temperature setback one-or two-pipe systems,indicate controls <br /> that provide heating water temperature <br /> setback based on outdoor temperature <br /> C403.4.4 Hydronic system part For heating and chilled water systems with>_ <br /> load controls and 300,000 Btu/h output capacity,indicate <br /> supply-water system controls are configured to <br /> temperature reset automatically reset supply water temperature <br /> based upon demand;or exception applied <br /> Indicate automatic pump flow controls are <br /> configured to reduce system flow rate by <br /> 50%,or the maximum allowed by the <br /> equipment manufacturer,based upon the <br /> heating or cooling loads;or decribe why not <br /> required <br /> For hydronic systems with output capacity Z <br /> 300,000 Btu/h that serve heating water <br /> systems,chilled water systems and water- <br /> cooled unitary air conditioners,indicate that <br /> pumps are provided with a variable speed <br /> drive if one of the following conditions apply: <br /> 1)System pump motor hp is>_2 hp and <br /> pumps are designed to operate continuously or <br /> per time schedule;2)System pump motor hp <br /> is>_7.5 hp and pumps are controlled by <br /> automatic DDC configured to only operate <br /> pumps when there is a call for zone heating or <br /> cooling <br /> Where variable speed drives are required, <br /> indicate system is configured so that pump <br /> motor power is<30%of design wattage at <br /> 50%of design flow rate;indicate pump flow <br /> is controlled to maintain one control valve <br /> nearly wide open,or to maintain a mimimum <br /> differential pressure;or exception applied <br /> C403.4.6 Hydronic system For individual pumps required to have <br /> variable pump flow variable speed controls,indicate manner of <br /> control pump speed control(differential pressure, <br /> static pressure setpoint,zone heating or <br /> cooling demand,or based on the relationship <br /> between variable speed controller fequency <br /> and power) <br /> C403.4.5 Chiller/boiler plant Indicate controls are configured to <br /> pump isolation automatically reduce overall plant flow and <br /> shut-off flow through individual chillers and <br /> boilers when not in use <br /> Page 16125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.