My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • 22 of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> If complying via high efficiency heating water <br /> plant:Indicate all VAV terminals have <br /> hydronic heating coils served by a heating <br /> water system with either gas-fired boiler(s) <br /> with thermal efficiency(Et)Z 92%,air-to- <br /> water heat pumps,or heat recovery chillers; <br /> indicate hydronic heating coils are sized per a <br /> maximum 120°F entering water temperature <br /> during peak demand <br /> If complying via high efficiency chilled water <br /> plant:Indicate all VAV air handlers have <br /> cooling coils served by chillers with rated <br /> IPLV efficiency that exceeds WSEC listed <br /> IPLV by at least 25%per Table C403.3.2(7) <br /> (note water-cooled IPLV is max,all others are <br /> min);indicate smallest chiller or compressor <br /> in plant is<20%of the total plant capacity, <br /> or provide thermal storage sized for>20%of <br /> total plant capacity <br /> C403.6.10, Fault detection and Indicate DDC system includes automatic fault <br /> Item 15 diagnostics detection and diagnostics(FDD)configured <br /> to monitor operation and provide fault <br /> reporting of all required parameters for all <br /> VAV air handlers and VAV air terminal units <br /> in the HPVAV system <br /> HIGH EFFICIENCY SINGLE-ZONE VAV SYSTEMS-EXCEPTION TO C403.3.5 DOAS,MUST COMPLY WITH ALL 8 PROVISIONS TO <br /> BE ELIGIBLE <br /> C403.12, Air economizer Indicate system is configured for 100%air <br /> Item 1 economizer operation and complies with all <br /> related economizer requirements per C403.5 <br /> (without economizer exceptions) <br /> C403.12, Direct digital controls Provide DDC controls for all components of <br /> Item 2 (DDC) system per C403.4.11 (regardless of system <br /> size);identify all DDC system input/output <br /> control points;indicate capability for trending <br /> and graphical display <br /> C403.12,Item Outdoor airflow For systems with minimum required outdoor <br /> 3 measurement and air> 1,000 cfm,provide an airflow <br /> control monitoring station that is configured to <br /> measure outdoor air intake under all load <br /> conditions;indicate controls that adjust <br /> outdoor air cfm via DCV per C403.7.1 <br /> C403.12,Item Maximum allowable For each single-zone VAV system,provide <br /> 4 system brake calculations that verify total fan system bhp is <br /> horsepower <90%of the total allowable fan system bhp <br /> per Option 2 equation in Table C403.8.1.1 <br /> C403.12, Supply airflow Provide controls that adjust supply airflow <br /> Item 5 control based on the heating and cooling loads; <br /> indicate control sequence that limits minimum <br /> fan speed to 30%of peak design airflow or <br /> required ventilation during unoccupied mode, <br /> whichever is less <br /> Page 22125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.