My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Unit Performance Data <br /> Indoor Fan Performance 4YCY4036 <br /> Horizontal Airflow <br /> 4YCY4036-HOR External Static Pressure(in.wg) <br /> Motor Speed 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 <br /> LOW Watts 162 173 197 226 256 285 313 343 383 440 525 <br /> CFM 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 <br /> VIED* Watts 179 230 265 296 329 366 403 431 450 485 555 <br /> CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 1144 <br /> HIGH Watts 1 318 1 336 1 365 1 399 1 435 1 469 1 502 1 533 1 563 - <br /> CFM 1 13901 13761 13701 13661 1361 1 13541 13491 1351 1 1369 - <br /> Down Airflow <br /> 4YCY4036-DOWN External Static Pressure(in. wg) <br /> Motor Speed 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 <br /> LOW Watts 169 182 210 243 273 301 331 370 433 480 530 <br /> CFM 1025 1062 1068 1063 1060 1061 1064 1055 1015 975 990 <br /> VIED* Watts 225 253 283 315 348 381 414 449 484 522 575 <br /> CFM 1187 1201 1203 1201 1198 1197 1194 1184 1157 1165 1150 <br /> HIGH Watts 1 339 1 357 1 390 1 424 1 455 1 483 1 516 1 571 1 669 - <br /> CFM 1 1391 1 13771 13771 13751 13661 13521 13441 13601 1340 <br /> *Factory Default Setting <br /> Heating Airflow, horizontal or downflow from .2 to .6"wg. <br /> 4YCY4036 *075 <br /> Switch Settings Selection Nominal Airflow <br /> Low Stage High Stage <br /> 7-OFF 8-OFF A 725 1000 <br /> TON 8-OFF B 775 1075 <br /> 7-OFF 8-ON C 850 1150 <br /> TON I 8-ON D 925 1250 <br /> * can be 1 or 3 <br /> 4YCY4036 *096 <br /> Switch Settings Selection Nominal Airflow <br /> Low Stage High Stage <br /> 7-OFF 8-OFF A 825 1100 <br /> 7-ON 8-OFF B 875 1175 <br /> 7-OFF 8-ON C 950 1275 <br /> TON I 8-ON D 1025 1375 <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.