My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Specifications <br /> General Condenser Coil— Heat Exchanger—stainless steel <br /> All units shall be factory assembled, The Spine Fin TM condenser coil shall be tubes. Free floating design. <br /> piped, internally wired and fully charged continuously wrapped, corrosion resistant Burners— stainless steel.Multi- <br /> with refrigerant.All units shall be de- all aluminum with minimum brazed joints. port inshot. <br /> signed to operate at outdoor ambient This coil is 3/8 inch OD seamless alumi- Accessories <br /> temperatures as high as 115°F. Cooling num tubing glued to a continuous alumi- (U.S.Domestic Models) <br /> capacities shall be rated in accordance num fin.Coils are lab tested to withstand Roof Curb—The roof curb shall <br /> with A.H.R.I.standards.The unit design 2,000 pounds of pressure per square be designed to mate with the unit <br /> is certified to ANSI 221.47/CSA 2.3 inch.The outdoor coil provides low airflow and provide support and complete <br /> specifically for outdoor applications resistance and efficient heat transfer. weather-tight installation when <br /> using natural gas or propane.All units The coil is protected on all four sides by properly installed.Curb shall ship <br /> shall be designed for outdoor rooftop or louvered panels. knocked down for field assembly, <br /> ground level installation.Unit casing is Indoor Air Fan—Direct-drive,forward- and include wood nailer strips. <br /> constructed of heavy gauge, galvanized curved, centrifugal wheel in a Composite <br /> steel and painted with a weather-resistant Vortice Blower housing.Motor shall Modulating Economizer—This <br /> powder paint. have thermal overload protection.Perma- accessory shall be field installed <br /> Shipped for horizontal application, nently lubricated motor bearings.Motor/ and be composed of the following <br /> convertible to downf low. blower assembly isolated from unit with items:0-100%fresh air damper, <br /> Casings rubber mounts. damper drive motor fixed dry bulb <br /> All panels shall be heavy gauge steel, Condenser Fan—Direct-drive, draw enthalpy control, and low voltage <br /> gasketed and insulated. Foil-faced through propeller type.Weather-proofed polarized plug for electrical con- <br /> insulation shall be in the heat exchanger permanent split capacitor fan motor shall nections.Solid state enthalpy or <br /> section. Foil-faced insulation shall be in have built-in thermal overload and perma- differential enthalpy control is op- <br /> the evaporator section.Base pan shall be nently lubricated motor bearings. tional.Economizer operations shall <br /> heavy gauge steel.WEATHERGUARDT"' Low Ambient—Standard refrigerant be controlled by the preset position <br /> of the enthalpy control.A barometic <br /> exterior corrosion resistant screws shall <br /> system operation down to 55°F.Low am- relief damper shall be standard <br /> be used for added resistance to rust and bient accessory required for operation to <br /> corrosion. with the economizer and provide <br /> 0o F ambient condition. a pressure operated damper that <br /> Controls shall be gravity closing and prohibit <br /> Refrigeration cycle controls shall include Gas-Fired Heating System—Models entrance of outside air on equip- <br /> condenser fan, evaporator fan and com- shall provide completely assembled, ment"off'cycle. <br /> pressor contactors.Compressors shall wired and piped gas fired heating systems Manual Fresh Air Hood <br /> be equipped with a combination internal within unit.Design certified by UL, specifi- Manual outside air provides a <br /> winding thermostat/current overload. cally for outdoor application.Threaded <br /> Internal high pressure relief shall also be fixed outside air quantity from 0 <br /> g p gas connection on the unit. to 25 percent. Includes hood and <br /> provided. Electronic Ignition System—Main birdscreen. <br /> Refrigeration System burner is lit each time thermostat calls for <br /> Compressors— gas heat. Flame sensor proves flame and Low Ambient Control <br /> Control allows cycling of compres <br /> The Climatuff®compressor features in- keeps the main burners on.Should a loss <br /> ternal over temperature and pressure pro- cor under low ambient cooling <br /> p p p of flame occur,the main valve closes and conditions.Required for cooling <br /> tector,total dipped hermetic motor.Other the spark recurs within 0.8 second.When operation to 0°F. <br /> features include:centrifugal oil pump, and thermostat is satisfied, main burner is <br /> low vibration and noise. extinguished. Propane Gas <br /> Evaporator Coil—Internally enhanced Conversion Kit—For conversion <br /> 3/8-inch OD seamless copper tubing Forced Combustion Blower in Insures from natural gas to LP gas. <br /> mechanically bonded to aluminum fins, flame stability under varying wind condi- <br /> factory pressure and leak tested at 250 nd l Gives higher combustion efficiency <br /> a <br /> to 300 psig.All units have TXV to control and location flexibility. <br /> refrigeration flow. <br /> `10 rek <br /> 1 <br /> / c ah rid rertery.o rg TCM <br /> UritarySmallAC <br /> . d.i 1 41 IIC <br /> C V V <br /> /STEM <br /> Trane <br /> 6200 Troup Highway The manufacturer has a policy of continuous product and product data improvement and it reserves the right <br /> Tyler,TX 75707-9010 <br /> to change design and specifications without notice. <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.