Laserfiche WebLink
Technical Data: F1 Res 30 LL Pendent and Recessed Pendent(SIN RA3311) <br /> Thread Nominal Orifice Max.Pressure Sprinkler Temp.Rating Max.Ambient Temp. Actual K Sprinkler Length <br /> Size Inch mmpsi(bar) OF °C OF °C Factor Inch mm <br /> 1/2"NPT 21/64"(8.2) 175(12) 155 68 100 38 3.0(43.2) 2.25(57) <br /> R1/z 175 79 <br /> Ordinary Temp.Rating Intermediate Temp.Rating <br /> Max. Minimum <br /> Max.Coverage area Spacing 155°F/68°C 175°F/79°C Top of Deflector to Ceiling Spacing <br /> Ft x Ft(m x m) Flow Pressure Flow Pressure Inch(mm) <br /> Ft(m) GPM L/min PSI(bar) GPM L/min PSI(bar) Ft(m) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 8(30.3) 7.0(0.48) 8(30.3) 7.0(0.48) Smooth Ceilings 1"to 4" <br /> 14 x 14(4.3 x 4.3) 14(4.3) 10(37.8) 11 (0.76) 10(37.8) 11 (0.76) (25mm to 100mm) 8(2.4) <br /> Beamed Ceilings per NFPA 13, <br /> 16 x 16(4.9 x 4.9) 16(4.9) 13(49) 18.8(1.3) 13(49) 18.8(1.3) 13D,or 13R <br /> Technical Data: F1 Res 49 LL Pendent and Recessed Pendent(SIN RA3316) <br /> Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler <br /> Pressure Tem .Ratin Ambient Temp. K Length <br /> Size Inch(mm) psi bar °F °C OF °C Factor Inch mm <br /> 16 <br /> 1/2"NPT 7/ "(11) 175(12) 155 68 100 38 4.9(70.6) 2.25(57) <br /> R1/z 175 79 150 66 <br /> Ordinary Temp.Rating Intermediate Temp.Rating Top of Deflector Minimum <br /> Max.Coverage area Max.Spacing 155°F/680C 1750F/790C to Ceiling Spacing <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Flow Pressure <br /> GPM min PSI a GPM min PSI Inch(mm) Ft(m) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 13(49) 7.0(0.48) 13(49) 7.0(0.48) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 13(49) 7.0(0.48) 13(49) 7.0(0.48) Smooth Ceilings 1"to 4" <br /> 16 x 16(4.9 x 4.9) 16(4.9) 13(49) 7.0(0.48) 13(49) 7.0(0.48) (25mm to 100mm) 8(2.4) <br /> Beamed Ceilings per NFPA <br /> 18 x 18(5.5 x 5.5) 18(5.5) 17(64.3) 12(0.83) 17(64.3) 12(0.83) 13, 13D,or 13R <br /> 20 x 20(6.1 x 6.1) 20(6.1) 20(75.7) 16.7(1.14) 20(75.7) 16.7(114) <br /> Ordinary Temp.Rating Intermediate Temp.Rating Top of Deflector Minimum <br /> Max.Coverage area Max.Spacing 155°F/68°C (175*F/79'C) to <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Flow Pressure In Ceiling Spacing <br /> GPM min PSI GPM min PSI(badInch(mm) Ft(m) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 15(57) 9.4(0.65) 15(57) 9.4(0.65) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 16(60.5) 10.6(0.73) 16(60,5) 10.6(0.73) <br /> 16 x 16(4.9 x 4.9) 16(4.9) 17(64.3) 12.0(0.83) 17(64.3) 12.0(0.83) Smooth Ceilings 4"to 8" 8(2.4) <br /> (100mm to 200mm) <br /> 18 x 18(5.5 x 5.5) 18(5.5) 19(72) 15.0(1.0) 19(72) 15.0(1.0) <br /> 20 x 20(6.1 x 6.1) 20(6.1) 22(83.2) 20.2(1.4) 22(83.2) 20.2(1.4) <br /> 3. <br />