Laserfiche WebLink
Technical Data: F1 Res 30 LL CCP Pendent and Recessed Pendent/FP (SIN RA3311) <br /> Thread Nominal Max. CCP Assembly Max. K Sprinkler <br /> Orifice Pressure Temp. atin Ambient Temp. Length <br /> Size Inch mm psi(bar) OF °C OF oC Factor Inch mm <br /> 1/2"NPT 21/64"(8.2) 175(12) 135 57 100 38 3.0(43.2) 2.25(57) <br /> (RI/2) <br /> Ordinary Temp.Rating Minimum <br /> Max.Coverage area Max.Spac- 1550F/68°C Top of Deflector to Ceiling Spacing <br /> Ft x Ft(m x m) ing Ft(m) Flow Pressure Inch(mm) Ft(m) <br /> GPM(L/min) PSI bar <br /> 12 x 12(3.6 x 3.6) 12(3.6) 8(30.3) 7.0(0.48) Smooth Ceilings 1/2"to 1" <br /> (13mm to 25mm)using CCP or FP escutcheon 8(2.4) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 11 (37.8) 13.4(0.92) Beamed Ceilings per NFPA 13, 13D,or 13R <br /> Technical Data: F1 Res 49 LL CCP Pendent and Recessed Pendent/FP (SIN RA3316) <br /> Thread Nominal Max. CCP Assembly Max. K Sprinkler <br /> Orifice Pressure Temp.RatingAmbient Temp. Length <br /> Size Inch(mm) psi(bar) OF °C OF oC Factor Inch(mm) <br /> 1/2 NPT 7/16"(11) 175(12) 135 57 100 38 4.9(70.6) 2.25(57) <br /> (R1/z) <br /> Max.Coverage Ordinary Temp.Rating Minimum <br /> ea Max.Spacing (155°F/68°C) Top of Deflector to Ceiling <br /> Ft x Ftr(m x m) Ft(m) Flow Pressure Inch(mm) Spacing <br /> (m)g <br /> GPM(L/min) PSI(bar) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 13(49) 7.0(0.48) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 13(49) 7.0(0.48) <br /> Smooth Ceilings 1/2"to 1" <br /> 16 x 16(4.9 x 4.9) 16(4.9) 14(53) 8.2(0.56) (13mm to 25mm)using CCP or FP 8(2.4) <br /> escutcheon <br /> 18 x 18(5.5 x 5.5) 18(5.5) 18(68.1) 13.5(0.93) Beamed Ceilings per NFPA 13, 13D,or 13R <br /> 20x20(6.1 x6.1) 20(6.1) 20(75.7) 16.7(1.14) <br /> Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in <br /> the space above. <br /> Technical Data: F1 Res 58 LL CCP Pendent and Recessed Pendent/FP (SIN RA3313) <br /> Thread Nominal Max. CCP Assembly Max. K Sprinkler <br /> Orifice Pressure Temp.Rating Ambient Temp. Length <br /> Size Inch(mm) psi(bar) OF °C OF OC Factor Inch(mm) <br /> 1/z"NPT 1/2"(13) 175(12) 135 57 100 38 5.8(83.5) 2.25(57) <br /> (R1/z) <br /> Max.Coverage Ordinary Temp.Rating Minimum <br /> Max.Spacing (155°F/680C) Top of Deflector to Ceiling <br /> area Ft(m) Flow Pressure Inch(mm) Spacing <br /> Ft x Ft(m x m) GPM(L/min PSI(bar) Ft(m) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 16(61) 7.6(0.53) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 16(61) 7.6(0.53) <br /> Smooth Ceilings 1/2"to 1" <br /> 16 x 16(4.9 x 4.9) 16(4.9) 16(61) 7.6(0.53) (13mm to 25mm)using CCP or FP escutcheon 8(2.4) <br /> Beamed Ceilings per NFPA 13, 13D,or 13R <br /> 18 x 18(5.5 x 5.5) 18(5.5) 19(72) 10.8(0.75) <br /> 20x20(6.1 x6.1) 20(6.1) 22(83.3) 14.4(1.0) <br /> 5. <br />