My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9920 18TH AVE W C 2025-04-07
>
Address Records
>
18TH AVE W
>
9920
>
9920 18TH AVE W C 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2025 11:58:55 AM
Creation date
3/4/2025 1:56:37 PM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9920
Unit
C
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Technical Data: F1 Res 44 LL SWC (SIN RA3331) continued <br /> Ordinary Temp.Rating Top of Deflector to Minimum <br /> Max.Coverage area Max.Spacing 155°F/68°C <br /> Ft x Ft(m x m) Ft(m) Flow Pressure Ceiling Spacing <br /> GPM(Vmin) PSI bar Inch(mm) Ft(m) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 13(49.2) 8.7(0.60) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 14(53.0) 10.2(0.71) <br /> 16 x 16(4.9 x 4.9) 16(4.9) 17(64.3) 15.0(1.1) 4 to 6(100 to 152) <br /> 16 x 18(4.9 x 5.5) 16(4.9) 19(71.8) 18.7(1.13) <br /> 16 x 20(4.9 x 6.1) 16(4.9) 23(87.1) 27.4(1.89) 8(2.4) <br /> 12 x 12(3.6 x 3.6) 12(3.6) 14(52.9) 10.2(0.71) <br /> 14 x 14(4.3 x 4.3) 14(4.3) 15(56.7) 11.7(0.81) <br /> 6 to 12(152 to 305) <br /> 16 x 16(4.9 x 4.9) 16(4.9) 18(68.1) 16.8(1.16) <br /> 16 x 18(4.9 x 5.5) 16(4.9) 20(75.6) 20.7(1.43) <br /> Maintenance Model F1 Res 49 LL & 58 LL Recessed <br /> Model F1 Res 30 LL, 49 LL, F1 Res 58 LL and F1 Res 44 <br /> LL Sprinklers should be inspected and the sprinkler sys- Pendent/F1 <br /> tem maintained in accordance with NFPA 25, 13, 13D, and Model F1 Res 30 LL, 49 LL&58 LL Recessed <br /> 13R. Do not clean sprinkler with soap and water,Ammonia Pendent/F2 <br /> or any other cleaning fluids. Remove dust by using a soft Model F1 Res 30 LL, 49 LL&58 LL Recessed <br /> brush or gentle vacuuming. Replace any sprinkler which pendent/FP Specifications <br /> has been painted (other than factory applied)or damaged Sprinklers shall be [cULus Listed] [WaterMark Certified <br /> in any way, A stock of spare sprinklers should be main- WMCS] low flow residential recessed pendent sprinklers <br /> tained to allow quick replacement of damaged or operated engineered to provide a minimum design density of 0.05 <br /> sprinklers. Prior to installation, sprinklers should remain <br /> in the original cartons and packaging until used. This will gpm/ft2 over the listed coverage area. Listed flows as <br /> minimize the potential for damage to sprinklers that could specified by the manufacturer's technical data sheets are <br /> cause improper operation or non-operation. to be used. Residential sprinklers shall be installed in con- <br /> formance with the manufacturers installation guidelines <br /> Model F1 Res 30 LL, 49 LL & 58 LL Pendent and the applicable installation standard. Deflector-to-ceil- <br /> Sprinkler Specifications ing distance listing shall be 1"to 4" maximum, unless spe- <br /> Sprinklers shall be [cULus Listed] [WaterMark Certified cifically listed otherwise.Sprinkler frame and deflector shall <br /> WMCS] low flow residential pendent sprinklers engineered be of bronze frame construction having a '/2" NPT thread. <br /> to provide a minimum design density of 0.05 gpm/ft2 over Water seal assembly shall consist of a PTFE-coated Bel- <br /> the listed coverage area. Listed flows as specified by the leville spring washer with top-loaded extruded or cold <br /> manufacturer's technical data sheets are to be used. Resi- head cup with 3 mm glass bulb containing no plastic parts, <br /> dential sprinklers shall be installed in conformance with the and having a temperature rating of [155°F (68°C)] [175°F <br /> manufacturer's installation guidelines and the applicable (79°C)], Sprinklers shall have a nominal K-factor of 3.0,4.9 <br /> installation standard. Deflector-to-ceiling distance listing & 5,8. Standard finish; [Bronze] [Chrome-plated] [White <br /> shall be 1" to 4" maximum, unless specifically listed other- Polyester] [Special finish-specify]. Recessed escutcheon <br /> wise.Sprinkler frame and deflector shall be of bronze frame assembly shall be a steel, two-piece escutcheon [with 1/2" <br /> construction having a'/2" NPT thread. Water seal assembly adjustment(Model F2)] [with 3/4"adjustment(Model F1)] [of <br /> shall consist of a PTFE-coated Belleville spring washer with push-on and thread off design with '/2" adjustment (Model <br /> top-loaded extruded or cold head cup with 3 mm glass FP)]. Standard finish shall be [brass][bright chrome] [white <br /> bulb containing no plastic parts, and having a temperature painted]. Residential recessed pendent sprinklers shall be <br /> rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall Reliable [Model F1 Res 30 LL, 49 LL & 58 LL Recessed <br /> have a nominal K-factor of 3.0, 4.9 and 5.8. Standard fin- Pendent/F1] [Model F1 Res 30 LL,49 LL&58 LL Recessed <br /> ish: [Bronze] [Chrome-plated] [White Polyester] [Special Pendent/1`21 [Model F1 Res 30 LL,49 LL&58 LL Recessed <br /> finish- specify]. Residential pendent sprinklers shall be Pendent/FP]SIN RA3311,RA3316&RA3313(Bulletin 033). <br /> Reliable Model F1 Res 30 LL, 49 LL&58 LL, SIN RA3311, <br /> RA3316& RA3313(Bulletin 033). <br /> 8. <br />
The URL can be used to link to this page
Your browser does not support the video tag.