Model RFC49& RFC49LL • Sprinklers RFC49: SINRA0616 <br /> RFC49LL: SINRA3216 <br /> Technical Specifications Sensitivity <br /> Style:Flat Concealed Pendent Fast-response <br /> Threads:1/2"NPT or ISO 7-1 R1/2 y <br /> Nominal K-Factor:4.9(71 metric) Temperature Rating <br /> Max.Working Pressure: 175 psi(12 bar) Ordinary: <br /> Min.Spacing:8 ft.(2.4 m) 165°F(74°C)sprinkler <br /> 135°F(57°C)cover plate <br /> Material Specifications Intermediate: <br /> Thermal Sensor:Nickel Alloy Solder Link 212°F(100°C)sprinkler <br /> Sprinkler Body:Brass Alloy 165°F(74°C)cover plate 11 Fwxi <br /> Levers:Bronze Alloy <br /> Yoke:Brass Alloy Cover Plate <br /> Sealing Assembly:Nickel Alloy with PTFE Model RFC cover plate <br /> Load Screw:Bronze Alloy <br /> Towers:Copper Alloy Sprinkler Wrench <br /> Pins:Stainless Steel Model FC(without wrench-able cap) (f►' <br /> Deflector:Bronze Alloy Model W3(with wrench-able cap) Bottom View <br /> Cup:Steel <br /> Cover Plate Finishes Listings and Approvals <br /> cULus Listed to UL 1626 .Y�.•+ <br /> (See Table H) cULus Certified for Health Effects to NSF/ANSI <br /> Standard 61 Annex G(RFC49LL only) <br /> Watermark Certified RFC49LL only) <br /> Model RFC49&RFC49LL Sprinkler Components and Dimensions <br /> 2-5/16"(58 mm)y <br /> Threads Dia. <br /> Body = _ <br /> Cup _ <br /> Tower 1-3/4"(44 mm)+/-1/4"(6 mm) <br /> Fusible Link Nominal face of fitting to ceiling <br /> Deflector(retracted) 3/16"(5 mm, <br /> Pin(extended) <br /> Deflector(extended) �� <br /> Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling <br /> Model RFC49&RFC49LL Sprinkler Hydraulic Design Criteria <br /> Minimum Flow and Residual PressureM <br /> Max.Coverage Area(2) <br /> Ordinary Temperature Intermediate Temperature <br /> ft.x ft. Flow Pressure Flow Pressure <br /> (m x m) gpm psi gpm psi <br /> (1/min) (bar) (1/min) (bar) <br /> 16 x 16 13 7.0 13 7.0 <br /> (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) <br /> 18 x 18 17 12.0 17 12.0 <br /> (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) <br /> 20 x 20 20 16.7 21 18.4 <br /> (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) <br /> Notes: <br /> 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table D above and(2)the flow required to <br /> achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. <br /> 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. <br /> Bulletin 006 Reliable Page 4 of 8 <br /> May 2019 www.reliablesprinkler.com <br />