My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7400 HARDESON RD SUNBELT RENTALS 2025-07-18
>
Address Records
>
HARDESON RD
>
7400
>
SUNBELT RENTALS
>
7400 HARDESON RD SUNBELT RENTALS 2025-07-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2025 7:23:34 AM
Creation date
3/6/2025 2:05:54 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7400
Tenant Name
SUNBELT RENTALS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RESPONSE:The structural building plans submitted with the initial permit package were preliminary <br /> drawings. The final drawings and structural calculations are enclosed in the attached REV1 submittal <br /> package which address the structural building comments. <br /> 5.The seismic load should include a vertical seismic component concurrent with the horizontal <br /> loading. The vertical component should be applied in both directions; the upward force is <br /> anticipated to create the worse-case loading for the columns, base components, and <br /> anchorage. See the seismic load combinations of ASCE 7-16 Section 12.4.2.2. <br /> RESPONSE:The structural building plans submitted with the initial permit package were preliminary <br /> drawings. The final drawings and structural calculations are enclosed in the attached REV1 submittal <br /> package which address the structural building comments. <br /> 6.The columns may have protected zones depending on the revised system selected, such as the <br /> base of the column for special cantilever columns per AISC 341-16 Section E6.5c. Holes, welds, <br /> and other connections are not permitted in the protected zones.The extents of the protected <br /> zones should be shown in a detail. See IBC Section 2205.2.1.2. <br /> RESPONSE:The structural building plans submitted with the initial permit package were preliminary <br /> drawings. The final drawings and structural calculations are enclosed in the attached REV1 submittal <br /> package which address the structural building comments. <br /> 7. It is anticipated that a special seismic system may be used, such as the special steel cantilever <br /> column system of AISC 341-16 Section E6.The following comments should be addressed: <br /> a.The design should comply with the requirements of ductile members where applicable. See <br /> Section D1.1. <br /> b.The columns should comply with the aspect ratio limits per Table D1.1. <br /> c. Design and detailing for the column base connections, including but not limited to the base <br /> plates and welds, are required to be designed per Section D2.6. <br /> d. Design of the columns considering seismic over strength. <br /> RESPONSE:The structural building plans submitted with the initial permit package were preliminary <br /> drawings. The final drawings and structural calculations are enclosed in the attached REV1 submittal <br /> package which address the structural building comments. <br /> Joe Flynn <br /> Wilcox Construction Inc.' Project Manger <br /> 234 5th Ave South, Edmonds WA 98020 <br /> Cell: 206-817-0263 1 Office: 425-774-4185 1 Fax:425-774-4187 <br />
The URL can be used to link to this page
Your browser does not support the video tag.