My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7400 HARDESON RD SUNBELT RENTALS 2025-07-18
>
Address Records
>
HARDESON RD
>
7400
>
SUNBELT RENTALS
>
7400 HARDESON RD SUNBELT RENTALS 2025-07-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2025 7:23:34 AM
Creation date
3/6/2025 2:05:54 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7400
Tenant Name
SUNBELT RENTALS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8/24/2021 <br /> IBC 2018 METAL BUILDING ANCHOR BOLT AND FOUNDATION DESIGN 8:49 AM <br /> Version Date.November 23,2020 By: SDP Reviewed by: TMD <br /> JOB TITLE:Everett WA Sunbelt Wash Bay JOB#: 21114 <br /> Column:Typical DESIGNER: NGW <br /> ANCHOR BOLT REACTIONS AND LOAD COMBINATIONS <br /> Y Z x DESIGN SUMMARY: <br /> •ea• •.1 r.r <br /> Collateral,C 0.2 0.0 0.0 <br /> Floor Live 0.0 0.0 0.0 Thrust Resistance: <br /> Roof Live 3.0 0.3 0.0 <br /> Crane,Cr 0.0 0.0 0.0 Grade Beam N/A <br /> Snow 4.5 0.4 0.0 -OR- <br /> Wind 0.7 1.3 0.8 Hairpin N/A <br /> Wind(Uplift) 2.6 2.3 0.8 <br /> Seismic 0.6 0.4 0.3 Friction+Passive Pressure Checked at footing <br /> Seismic(Uplift) 0.6 0.4 0.3 <br /> Seismic Design Factors Seismic Design Category <br /> Seismic Coefficient Sds 1 0.82 D I Anchor Bolts: <br /> Amplification Factor-t!o 3 Use 1!o= .0 d Design Cal.is A or B <br /> Redundancy Factor-p 1.3 (4)0.75 in diameter x 8 in embed A36 headed A.B. <br /> ASD Combinations ASCE 7.16 C• "1-D-eactrons <br /> D 1 0.7 0.1 0.0 X.Oireetion P;hn•emm <br /> D*L+Cr 2 0.7 0.1 0.0 Shear Confined Confined <br /> D+C+Lr 3 3.9 0.4 0.0 OK OK <br /> D+C+S 4 5.4 0.5 0.0 <br /> D+C+0.75'(L+Cr)+0.75`Lr 5 3.2 0.3 0.0 55 <br /> D+C+0.75'(L+Cr)+0.75`5 6 4.3 0.4 0.0 Tension Confined <br /> D+0.6'W 7 1.1 0.9 0.5 OK 0.03 <br /> D-0.6'W 8 -0.9 -1.3 -0.5 <br /> (D+0.14`Sds`0)+0.7•(E`p) 9 1.3 0.5 0.3 Combined OK 0.03 <br /> (0-0.14'Sds'D)-0.7`(E`p) 10 0.1 -0.3 -0.3 <br /> D+C+0.75`0.6`W+0.75'(L+Cr)+0.75'Lr 11 3.5 0.9 0.4 <br /> D+C-0.75'0.6'W+0.75'(L+Cr)+0.75`Lr 12 2.0 -0.7 -0.4 Pier: <br /> D+C+0.75`0.6'W+0.75'(L+Cr)+o.75`S 13 4.6 1.0 0.4 <br /> D+C-0.75'0.6'W+0.75'(L+Cr)+0.75•S 14 3.1 -0.6 -0.4 17 in wide x 24 in long-3000 psi concrete <br /> (D+0.105`Sds*D)+0.525'(E'p)+C+0.75'(L+Cr)+0.75`Lr 15 3.6 0.6 0.2 (8)#5 Vertical Bars with 6 in hook embedment in footing <br /> (0-0.105'Sds'D)-0.525'(E'p)+C+0.75`(L+Cr)+0.75`Lr 16 2.7 0.0 -0.2 #3 Ties at 10 in o.c.with(3)in top 5 in <br /> (D+0.105'Sds`D)+C+0.525'(E'p)+0.75`(L+Cr)+0.75'S 17 4.7 0.7 0.2 <br /> (0-0.105'Sds`D)*C-0.525'(E'p)+0.75`(L+Cr)+0.75'S 18 3.8 0.1 -0.2 56 <br /> 0.6D+0.6`W 19 0.8 0.8 0.5 Tension n 0.01 <br /> 0.6D-0.6'W 20 -1.1 -1.3 -0.5 <br /> 0.6'(D+0.14'Sds'D)+0.7'(E'p) 21 1.0 0.4 0.3 Compression - 0.02 <br /> 0.61D-0.14'Sds'D)-0.7'(E'p) 22 -0.2 -0.3 -0.3 <br /> Flexure 0.08 <br /> Maximum ASD Reactions 5.4 1.0 0.5 <br /> Minimum ASD Reactions(-V indicates uplift) -1.1 -1.3 -0.5 Min/Max Reinforcement n <br /> LRFD Combinations LC# LRFD Reactions <br /> 1.40 1 1.0 0.1 0.0 Footing: <br /> 1.2D+1.6(L+C,)+0.55 2 3.3 0.3 0.0 <br /> 1.2D*1.6(L+C,)+0.5L,+C 3 2.5 0.3 0.0 3 ft square x 12 in thick-3000 psi concrete <br /> 1.2D+1.6'(L,+C)+L+C, 4 6.0 0.6 0.0 (3)#5 bottom bars each way <br /> 1.2D+1.6(L,+C)+0.5W 5 6.3 1.3 0.4 (3)#5 top bars each way <br /> 1.2D+1.6(L,+C)-0.5W 6 4.7 -0.6 -0.4 <br /> 1.2D+1.6(C+S)+(L+C,) 7 8.4 0.8 0.0 5H <br /> 1.2D+1.6(C+S)+0.5W 8 8.7 1.4 0.4 Sliding 0.40 <br /> 1.2D+1.6(C+S)-0.5W 9 7.1 -0.4 -0.4 <br /> 1.2D+1.0W+(L+C,)+0.5L,+C 10 3.2 1.6 0.8 Overturning ON 0.91 <br /> 1.20-1.0W+(L+C,)+0.5L,+C 11 -0.1 -2.0 -0.8 <br /> 1.20+1.0W+(L+C,)*0.55+C 12 4.0 1.6 0.8 Soil Pressure "ry 0.70 <br /> 1.20-1.0W+(L+C,)+0.5S+C 13 0.7 -2.0 -0.8 <br /> 12'(D+0.2'Sds'D)*(E`p)+(L+C,)+0.2S+C 14 2.9 0.7 0.4 Uplift 0, 0.39 <br /> 1.2'(DD-0.2'Sds'D)-(E'p)+(L+C,)+0.25+C 15 0.8 -0.3 -0.4 <br /> 1.2'(D+0.2'Sds'D)*(E`I:o)*(L*C)+0.25+C 16 3.9 1.4 0.9 One Way Shear 1K 0.82 <br /> 1.2`(D-0.2'Sds`D)-(E`(!o)*(L+C)*0.2S*C 17 -0.2 -1.0 -0.9 <br /> 0.9D+1.0W iB 1.3 1.4 0.8 Punching Shear 0,. 0.04 <br /> 0.9D-1.0W 19 -2.0 -2.2 -0.8 <br /> 0.9'(0+0.2'Sds'D)*(E'p) 20 1.5 0.6 0.4 Flowre .Jo 0.16 <br /> 0.9`(0-0.2`Sds`D)-(E`p) 21 -0.3 -0.4 -0.4 <br /> 0.9*(D+0.2'Sds'D)+(E'1!o) 22 2.5 1.3 0.9 Thickness for hooked bars �r <br /> 0.9•(D-0.2`Sds'D)-(E'(!o) 23 -1.3 -1.1 -0.9 <br /> Reinforcement .0* <br /> Ilammum LRFD Reactions 8.7 1.6 0.9 <br /> Minimum LRFD Reactions(-V indicates uplift) -2.0 -2.2 -0.9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.