My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7400 HARDESON RD SUNBELT RENTALS 2025-07-18
>
Address Records
>
HARDESON RD
>
7400
>
SUNBELT RENTALS
>
7400 HARDESON RD SUNBELT RENTALS 2025-07-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2025 7:23:34 AM
Creation date
3/6/2025 2:05:54 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7400
Tenant Name
SUNBELT RENTALS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8/24/2021 <br /> IBC 2018 METAL BUILDING FOOTING DESIGN 8:49 AM <br /> version Date:November 23,2020 By: SDP Reviewed by: TMD <br /> JOB TITLE:Everett WA Sunbelt Wash Bay JOB#: 21114 <br /> Column:Typical DESIGNER: NOW <br /> Footing Design <br /> $oil Pronertleo $IjQIB9IOvertrminn Proor•rtl•.‘ <br /> Allowable sod bearing pressure 1,500 psf Is there a foundation wall between piers? NO <br /> Is this Net bearing pressure? YES Foundation width used for passive to resist Z-Direction force 4 ft <br /> %Allowable pressure increase for Wind&Seismic 33 % Available passive pressure per foot of foundation wall length 0.0 k8 <br /> Soil density y,a,: 110 pcf Available passive pressure per foot of footing width 0.9 kd <br /> Concrete-Soil Friction Coefficient p: 0.35 Total available passive force 2.6 k <br /> Passive Pressure EFP 350 pcf Top of pier to top of footing 24 in <br /> Top of grade to top of footing 24 in <br /> Allowable soil bearing pressure with increase 1,865 psf <br /> Allowable soil bearing pressure with increase W/E 2,480 psf <br /> Max%of Friction to use(per geolechnical report) 100 % <br /> Max%of passive to use(per geotechnical report) 100 % <br /> Safety factor to use for sliding: 1.5 <br /> Safety factor to use for W/E sliding: 1.5 <br /> Safety factor to use for overtuming: 1.0 <br /> footina Si'e Safety factor to use for W/E overturning: 1.0 <br /> Width and Length 3.0 ft <br /> Thickness 12 in <br /> Thick enough for pier dowels? YES <br /> Footing and Soil Dead Load 3.3 k <br /> %of Soil DL to use in ASCE 7-10 uplift combinations 90 % <br /> %of Footing DL to use in ASCE 7-10 uplift combinations 90 % <br /> Footing and Sod Dead Load for ASCE 7-10 Combinations 3.0 k <br /> Concrete compressive strength f,: 3,000 psi <br /> Feotina Relnfemina fontlna Bending <br /> Footing reinforcing fy: 60,000 psi Bottom reinforcement A,+: 0.93 ire Reinf.Status )H <br /> Bottom Bars# 5 bars Top Reinforcement A,-: 0.93 in' Reinf.Status or. <br /> Number of bars each way 3 Flexural Capacity pMn+: 33.8 keft <br /> Uplift Flexural Capacity qMn-: 33.8 keft <br /> Top Bars# 5 bars <br /> Number of bars each way 3 <br /> Footing Gear cover 3.0 in <br /> Footing effective depth d: 8.4 in <br /> Fnntlne Punehlne ahaar foptlna One Wee Sheer <br /> Width of critical shear perimeter II to Mu b,: 32.4 in Design shear capacity OVr:RUM k <br /> Width of critical shear perimeter 1 to Mu bz: 25.6 in <br /> Punching shear critical perimeter bo: 115.5 in <br /> Fraction of moment transferred by shear yv: 0.43 <br /> Polar moment of inertia of critical perimeter J : 3656240 in <br /> Ratio of long to short side of pier 6. 1.4 <br /> Column location factor a,: 40 Interior Column <br /> Lightweight Concrete Factor 0: 1 <br /> Nominal punching shear capacity v, 219.1 psi <br /> Design punching shear capacity : 164.3 psi <br />
The URL can be used to link to this page
Your browser does not support the video tag.