My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7100 HARDESON RD Geotech Report 2025-03-06
>
Address Records
>
HARDESON RD
>
7100
>
Geotech Report
>
7100 HARDESON RD Geotech Report 2025-03-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2025 2:46:08 PM
Creation date
3/6/2025 2:44:17 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7100
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IGeotechnical Engineering Report lierracon <br /> Merrill Creek Operations Base Expansion Everett, Washington <br /> IDecember 14, 2020 Terracon Project No. 81205012 GeoReport <br /> I <br /> to a firm, unyielding condition when the moisture content is more than 2 percentage points above <br /> or below optimum. Optimum moisture content is the moisture content at which the maximum dry <br /> density for the material is achieved in the laboratory by the ASTM D1557 test procedure. <br /> I <br /> If inclement weather or in situ soil moisture content prevents the use of on-site material as <br /> I structural fill, we recommend use of materials specified in Fill Material Types for free-draining <br /> granular fill. <br /> I Stockpiled soils should be protected with polyethylene sheeting anchored to withstand local wind <br /> conditions and preservation of the soil's moisture content. <br /> I SHALLOW FOUNDATIONS <br /> I If the site has been prepared in accordance with the requirements noted in , the <br /> following design parameters are applicable for shallow foundations. <br /> IDesign Parameters — Compressive and Lateral Loads <br /> Description Spread Footing Wall Footing <br /> INet Allowable Bearing Pressure • <br /> al Structural Fill Over Native Soil 3,000 psf 3,000 psf <br /> IMinimum Dimensions 24 inches 18 inches <br /> Embedment Below Finished Grade 2 Minimum 18 inches Minimum 18 inches <br /> IApproximate Static Total Settlement From <1 inch <1 inch <br /> Foundation Loads For Condition Specified <br /> I Estimated Static Differential Settlement From <br /> Foundation Loads About 1/2 of total settlement <br /> Allowable Passive Pressure <br /> ICompacted Structural Fill or Free- 300 pcf(equivalent fluid unit weight) <br /> Draining Fill <br /> IAllowable Coefficient of Sliding Frictions 0.40 <br /> I <br /> I <br /> I <br /> Responsive • Resourceful ■ Reliable <br />
The URL can be used to link to this page
Your browser does not support the video tag.