Laserfiche WebLink
• <br /> . r <br /> CLIENT: <br /> _ NASH&ASSOCIATES WIND AND SEISMIC DESIGN DATA PROJECT: <br /> ARCHITECTS PER 2018 IBC DATE: <br /> NAME: <br /> WIND DESIGN CRITERIA <br /> DESIGN PER ASCE 7-16 <br /> I. NOMINAL/ULTIMATE WIND SPEED V/asd / Vult 85/110 mph <br /> 2. RISK CATEGORY II 1.00 <br /> 3. WIND EXPOSURE CATEGORY <br /> 4. INTERNAL PRESSURE GOEFFIGENT +/-55 <br /> 5. COMPONENTS AND CLADDING <br /> DESIGN PRESSURE +/- 16 psf <br /> BUILDINGS, STRUCTURES, AND PARTS THEREOF SHALL BE DESIGNED AND <br /> CONSTRUCTED IN ACCORDANCE WITH STRENGTH DESIGN, LOAD, AND RESISTANCE <br /> FACTOR DESIGN, ALLOWABLE STRESS DESIGN, EMPIRICAL DESIGN OR CONVENTIONAL <br /> CONSTRUCTION METHODS, AS PERMITTED BY THE APPLICABLE MATERIAL CHAI-'I1=R, SECTION 1604.1 <br /> BUILDINGS, STRUCTURES, AND PARTS THEREOF, SHALL BE DESIGNED TO WITHSTAND WIND LOADS <br /> A5 DEFINED IN SECTION 160q AND ASCE 7-16 <br /> WIND DESIGN PER PART 2 "ENCLOSED SIMPLE DIAPHRAGM BUILDINGS PER ASCE 7-16, SECTION 27.4 <br /> (BUILDING HEIGHT IS LESS THAN 160 FEET)- SIMPLIFIED METHOD <br /> 110 MPH ULTIMATE WIND SPEED <br /> USE Iq.6 PSF PER TABLE 27.5.1 "EXPOSURE B"- 110 MPH (LB- .05/1= I(4.6 ph- PAGE 288) <br /> WOOD DESIGN PER SECTIONS 2304-2306. STRUCTURES USING WOOD SHEAR WALLS <br /> AND DIAPHRAGMS TO RESIST WIND, SEISMIC, AND ALL OTHER LATERAL LOADS SHALL <br /> BE DESIGNED AND CONS i h.UGTED IN ACCORDANCE WITH AF 4 PA SDPWS AND PROVISIONS <br /> OF SECTIONS 2305-2306 <br /> SEISMIC DESIGN DATA <br /> DESIGN PER ASCE 7-16/CHAPTER II <br /> 1. SEISMIC IMPORTANCE FACTOR le 1.00 <br /> 2. SHORT PERIOD ACCELERATION Ss 1.5 *see footnote at bottom of page (D=1.0) <br /> 3. 1 SECOND ACCELERATION SI 0.748 *see footnote at bottom of page <br /> 4. SITE GLASS D (default class per IBC and section 11.4.3) <br /> 5. SPECTRAL RESPONSE GOEFFIGENT Sps O.q-72 *see footnote at bottom of page <br /> 6. SPECTRAL RESPONSE GOEFFICENT Sal 0.148 *see footnote at bottom of page <br /> 1. SEISMIC DESIGN CATEGORY D (per table 11.6-I AND table 11.6-2) <br /> 8. SEISMIC FORGE RESISTING SYSTEM PLYWOOD SHEAR WALLS <br /> q. DESIGN BASE SHEAR (see seismIc calculations) <br /> 10. SEISMIC RESPONSE GOEFFICENT Gs 0.13 <br /> II. RESPONSE MODIFICATION FACTOR R 6.5 <br /> 12. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORGE <br /> 13. RISK CATEGORY II (table 1.5-I) <br /> THE ANCHORAGE OF WALLS SUPPORTING CONSTRUCTION SHALL BE BE <br /> DESIGNED IN ACCORDANCE WITH ASCE 7-16, SECTION 12.14 <br /> IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C-F, COLLECTOR ELEMENTS <br /> AND THEIR CONNECTIONS TO VERTICAL ELEMENTS SHALL BE DESIGNED TO RESIST <br /> MAXIMUM EFFECTS AS SPECIFIED IN ASCE 1-16, SECTION 12.14 <br /> BASE SHEAR V= (F S05/R) 1^1 <br /> ANCHOR BOLTS: 5/8" DIA X 10", A30-1 OR BETTER IN/ 7" MIN. EMBEDMENT. V= 11041*BOLT <br /> * PER USGS, THE MAXIMUM Si IN THE STATE OF WASHINGTON IS 0.748. ALL SEISMIC DESIGN VALUES USED <br /> IN THIS ANALYSIS ARE BASED UPON THIS NUMBER. SINGE Si IS LESS THAN 0.15, THEN USE SEISMIC CATEGORY <br /> D IF RISK CATEGORY IS I, II, OR III <br /> 8003 118th Ave. NE. Kirkland, WA 98033 (425) 828-4117 <br /> WWW.NASH-ARCHITECTS.COM <br />