My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1815 HOLBROOK AVE 2025-03-06
>
Address Records
>
HOLBROOK AVE
>
1815
>
1815 HOLBROOK AVE 2025-03-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2025 3:54:14 PM
Creation date
3/6/2025 3:01:40 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLBROOK AVE
Street Number
1815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
179
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 Washington State Energy Code-Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Single Family-New&Additions(effective February 1, 2021) <br /> Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel <br /> normalization credits) and Table 406.3 (energy credits)to achieve the following minimum number of <br /> credits.To claim this credit,the building permit drawings shall specify the option selected and the <br /> maximum tested building air leakage, and show the qualifying ventilation system and its control sequence <br /> of operation. <br /> 1. Small Dwelling Unit: <br /> Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. <br /> Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. <br /> 2. Medium Dwelling Unit: <br /> All dwelling units that are not included in#1 or#3 <br /> 3. Large Dwelling Unit: <br /> Dwelling units exceeding 5,000 sf of conditioned floor area <br /> 4. Additions less than 500 square feet: <br /> All other additions shall meet 1-3 abov: <br /> Before selecting your credits on this Summary table, review the details in Table 406.3(Single Family), on page 4. <br /> Summary of Table R406.2 <br /> Heating Fuel Normalization Descriptions Credits-select ONE User Notes <br /> Options heating option <br /> 1 Combustion heating minimum NAECAb 0.0 ❑ <br /> 2 Heat pump` 1.0 CI _ Electric Heat Pump <br /> 3 Electric resistance heat only-furnace or zonal -1.0 ❑ <br /> 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ <br /> 5 'All other heating systems -1.0 ❑ <br /> Ener Credits-select ONE <br /> gy Energy Credit Option Descriptions energy option from each <br /> Options category_d <br /> 1.1 Efficient Building Envelope _ 0.5 ❑ <br /> 1.2 l Efficient Building Envelope 1.0 ❑ <br /> 1.3 j Efficient Building Envelope 0.5 0 _ <br /> 1.4 j Efficient Building Envelope _ 1.0 ❑ <br /> 1.5 Efficient Building Envelope 2.0 El <br /> 1.6 Efficient Building Envelope 3.0 ❑ <br /> 1.7 "Efficient Building Envelope 0.5 ❑ <br /> 2.1 lAir Leakage Control and Efficient Ventilation 0.5 0 <br /> 2.2 iAir Leakage Control and Efficient Ventilation 1.0 ❑ <br /> 2.3 ;Air Leakage Control and Efficient Ventilation 1.5 ❑ I <br /> 2.4 Air Leakage Control and Efficient Ventilation 2.0 El <br /> 3.1a High Efficiency HVAC 1.0 El <br /> 3.2 High Efficiency HVAC 1.0 El <br /> 3.3a High Efficiency HVAC 1.5 ❑ <br /> ---3.5_..-.._ High...Efficiency....HVAC---...................._..._......................-_-__._..............._._....._......._......_......_-...._......_....._.....-..._._.....1.5..................._.........__......_.._..0 ...-_......-_.� <br /> 3.4 iHi h EfficiencyHVAC 1.5 El <br /> 3.6a High Efficiency HVAC 2.0 El <br /> 4.1 !High Efficiency HVAC Distribution System 0.5 0 <br /> 4.2 tHigh Efficiency HVAC Distribution System 1.0 ❑ <br /> Prescriptive Path-Single Family 2018 Washington State Energy Code-R 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.