My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1815 HOLBROOK AVE Geotech Report 2025-03-06
>
Address Records
>
HOLBROOK AVE
>
1815
>
Geotech Report
>
1815 HOLBROOK AVE Geotech Report 2025-03-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2025 3:27:03 PM
Creation date
3/6/2025 3:25:46 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLBROOK AVE
Street Number
1815
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 9,2022 <br /> Page to of 15 <br /> Geotechnical Evaluation <br /> Wall Design Criteria <br /> "At-rest"Conditions(Lateral Earth Pressure—EFD') 55 pcf(Equivalent Fluid Density) <br /> "Active"Conditions(Lateral Earth Pressure—EFD') 35 pcf(Equivalent Fluid Density) <br /> Seismic Increase for "At-rest" Conditions 21H* (Uniform Distribution) 1 in 2,50o year <br /> (Lateral Earth Pressure) event <br /> Seismic Increase for "At-rest" Conditions 14H*(Uniform Distribution)1 in 50o year event <br /> (Lateral Earth Pressure) <br /> Seismic Increase for "Active" Conditions 7H*(Uniform Distribution) <br /> (Lateral Earth Pressure) <br /> Passive Earth Pressure on Low Side of Wall Neglect upper 2 feet,then 25o pcf EFD' <br /> (Allowable,includes F.S.=1.5) <br /> Soil-Footing Coefficient of Sliding Friction(Allowable; 0.40 <br /> includes F.S.=1.5) <br /> 'H is the height of the wall;Increase based on one in 50o year seismic event (io percent probability of being exceeded in <br /> 5o years), <br /> -,EFD—Equivalent Fluid Density <br /> The stated lateral earth pressures do not include the effects of hydrostatic pressure generated by <br /> water accumulation behind the retaining walls. Uniform horizontal lateral active and at-rest <br /> pressures on the retaining walls from vertical surcharges behind the wall may be calculated using <br /> active and at-rest lateral earth pressure coefficients of o.3 and o.5,respectively. A soil unit weight <br /> of 125 pcf may be used to calculate vertical earth surcharges. <br /> To reduce the potential for the buildup of water pressure against the walls, continuous footing <br /> drains (with cleanouts) should be provided at the bases of the walls. The footing drains should <br /> consist of a minimum 4-inch diameter perforated pipe, sloped to drain, with perforations placed <br /> down and enveloped by a minimum 6 inches of pea gravel in all directions. <br /> The backfill adjacent to and extending a lateral distance behind the walls at least 2 feet should <br /> consist of free-draining granular material. All free draining backfill should contain less than 3 <br /> percent fines (passing the U.S. Standard No. 200 Sieve)based upon the fraction passing the U.S. <br /> Standard No. 4 Sieve with at least 3o percent of the material being retained on the U.S. Standard <br /> No. 4 Sieve. The primary purpose of the free-draining material is the reduction of hydrostatic <br /> pressure. Some potential for the moisture to contact the back face of the wall may exist,even with <br /> treatment, which may require that more extensive waterproofing be specified for walls, which <br /> require interior moisture sensitive finishes. <br /> We recommend that the backfill be compacted to at least 90 percent of the maximum dry density <br /> based on ASTM Test Method D1557. In place density tests should be performed to verify <br /> adequate compaction. Soil compactors place transient surcharges on :he backfill. Consequently, <br /> only light hand operated equipment is recommended within 3 feet of AN so that excessive stress <br /> is not imposed on the walls. <br /> www.cobaltgeo.com (206)331-1097 <br />
The URL can be used to link to this page
Your browser does not support the video tag.