DOCUMENT 2.0
<br />`i it NOV 2 6 2022
<br />ES
<br />ICC-ES Evaluation Report
<br />www.icc-es-pmg.gm 1 (800) 423-65871 (562) 699-0543
<br />DIVISION: 13 00 00—SPECIAL CONSTRUCTION
<br />Section: 13 11 13—Below-Grade Swimming Pools
<br />REPORT HOLDER:
<br />LATHAM POOL PRODUCTS, INC. dba VIKING POOLS,
<br />BLUE HAWAIIAN POOLS, TRILOGY POOLS, LIBERTY
<br />COMPOSITE POOLS, NARELLAN POOLS, LATHAM
<br />GRAND, AND LATHAM SELECT
<br />www.Latham.com
<br />EVALUATION SUBJECT:
<br />LATHAM POOL PRODUCTS, INC. FIBERGLASS
<br />SWIMMING POOL AND SPA SHELLS
<br />1.0 EVALUATION SCOPE
<br />Compliance with the following codes:
<br />■ 2021, 2018, 2015, 2012 & 2009 International Building
<br />Code® (IBC)
<br />■ 2021, 2018, 2015, 2012 & 2009 International
<br />Residential Code® (IRC)
<br />■ 2021, 2018 & 2015 International Swimming Pool and
<br />Spa Code® (ISPSC)
<br />■ 2012 & 2009 International Plumbing Code® (IPC)
<br />■ 2018, 2015 and 2012 Uniform Swimming Pool, Spa &
<br />Hot Tub Cade® (USPSHTC)
<br />■ 2019, 2016, 2013 AND 2010 California Residential
<br />Code® (CRC)
<br />■ 2020 and 2017 Cdy of Los Angeles Residential Code®
<br />(LARC)
<br />■ 2013 Abu Dhabi International Building Code (ADIBC)t
<br />'The ADIBC is based on the 2009 IBC. 2009 IBC oode sections referenced
<br />in this report are the same sections in the AD IBC.
<br />Compliance with the following standards:
<br />■ ANSI/APSP/ICC 5-2011, Standard for Residential
<br />Inground Swimming Pools
<br />■ ANSI/APSP/ICC 3-2014, Standard for Permanently
<br />Installed Residential Spas and Swim Spas
<br />■ IAPMO/ANSI Z124.7-2013(R18), Prefabricated Plastic
<br />Spa Shells
<br />■ AC274, ICC-ES Acceptance Criteria for In -ground
<br />Residential, Fiber -reinforced Plastic Swimming Pools and
<br />Permanently Installed Plastic Spas, dated December 2006
<br />(editoriallyrevised July 2017)
<br />ESR-2014
<br />Effective Date: November 2021
<br />This listing is subject to re-examination in one year.
<br />A Subsidiary of the Intemational Code Council
<br />2.0 USES
<br />The fiberglass pool and spa shells are for recreational use
<br />as swimming pools or spas in residential applications with
<br />water circulated through a filter in a closed system. The
<br />pools comply with ANSI/APSP/ICC-5 as Type O or Type I
<br />pools. The spas comply with ANSI/APSP/ICC-3 and
<br />IAPMO/ANSI Z124.7.
<br />3.0 DESCRIPTION
<br />3.1 General:
<br />The fiberglass pool and spa shells consist of one-piece
<br />fiberglass construction shop- formed over a mold. The
<br />material is minimum 1/4-inch-thick (6.4 mm), fiberglass -
<br />reinforced plastic (FRP), composed of isophtalic resin,
<br />vinylester resin, fiberglass, and ceramic (ceramic in Viking
<br />Pools only). The surface finish is a neopentyl glycol gel
<br />coat.
<br />The overall dimensions, depths and capacities are
<br />shown in Table 1 for pools, Table 2 for spas and Table 3
<br />for models that are perrritted to be installed up to
<br />191/2 i n ch es (495 mm) aboveground.
<br />Notice: The pool and spa shells are designed to remain
<br />full of water at all times. The shell may be damaged if the
<br />water level is allowed to drop below the skimmer. When
<br />appreciable drawdown is noticed or if it becomes
<br />necessary to drain the pool or spa, contact Latham Pool
<br />Products Inc., or its dealers for instructions.
<br />3.2 Aboveground Pools and Spas:
<br />Models intended for installation up to 191/2 inches
<br />(495 mm) above ground, listed in Table 3, have vertical
<br />supports consisting of 1-inch-by-11/2-inch-by-36-inch-long
<br />(25 mm by 38 mm by 914 mm), Douglas fir, No. 2 mod
<br />members encapsulated in the FRP process at 41/rfoot
<br />(13372 mm) intervals.
<br />4.0 INSTALLATION
<br />4.1 General:
<br />The swimming pool and spa shells must be permanently
<br />installed in -ground or, in the case of the models shown in
<br />Table 3, up to 191/2 inches (495 mm) above ground. All
<br />plumbing and electrical installations must comply with the
<br />relevant codes in effect at the construction site at the time
<br />of construction.
<br />Subject to the code official's approval, the pool or spa
<br />shells may be installed without a soil investigation by a
<br />registered design professional, provided none of the
<br />following conditions is encountered atthe site:
<br />1. The existence of groundwater wilhin the excavation,
<br />where the pool or spa floor will contact the soil at the
<br />time of installation.
<br />Listings are not to be construed as representing aesthetic or any other attribraes not speafimLly addressed, nor are they to be con.wrual as an
<br />endorsement of the subject ofthe listing or a recommendation for its use. There ism warranty by 1CCEwheation Service. LLC, express rw implied, a� to
<br />an y fi nd rig or other mailer in this listing, or as to any product covered by the listing.
<br />Copyright© 2021 ICC Evaluation Service, LLC. All rights reserved.
<br />ll 5
<br />a�AAm
<br />gas v
<br />Page 1 of 5
<br />
|