Laserfiche WebLink
DOCUMENT 2.0 <br />`i it NOV 2 6 2022 <br />ES <br />ICC-ES Evaluation Report <br />www.icc-es-pmg.gm 1 (800) 423-65871 (562) 699-0543 <br />DIVISION: 13 00 00—SPECIAL CONSTRUCTION <br />Section: 13 11 13—Below-Grade Swimming Pools <br />REPORT HOLDER: <br />LATHAM POOL PRODUCTS, INC. dba VIKING POOLS, <br />BLUE HAWAIIAN POOLS, TRILOGY POOLS, LIBERTY <br />COMPOSITE POOLS, NARELLAN POOLS, LATHAM <br />GRAND, AND LATHAM SELECT <br />www.Latham.com <br />EVALUATION SUBJECT: <br />LATHAM POOL PRODUCTS, INC. FIBERGLASS <br />SWIMMING POOL AND SPA SHELLS <br />1.0 EVALUATION SCOPE <br />Compliance with the following codes: <br />■ 2021, 2018, 2015, 2012 & 2009 International Building <br />Code® (IBC) <br />■ 2021, 2018, 2015, 2012 & 2009 International <br />Residential Code® (IRC) <br />■ 2021, 2018 & 2015 International Swimming Pool and <br />Spa Code® (ISPSC) <br />■ 2012 & 2009 International Plumbing Code® (IPC) <br />■ 2018, 2015 and 2012 Uniform Swimming Pool, Spa & <br />Hot Tub Cade® (USPSHTC) <br />■ 2019, 2016, 2013 AND 2010 California Residential <br />Code® (CRC) <br />■ 2020 and 2017 Cdy of Los Angeles Residential Code® <br />(LARC) <br />■ 2013 Abu Dhabi International Building Code (ADIBC)t <br />'The ADIBC is based on the 2009 IBC. 2009 IBC oode sections referenced <br />in this report are the same sections in the AD IBC. <br />Compliance with the following standards: <br />■ ANSI/APSP/ICC 5-2011, Standard for Residential <br />Inground Swimming Pools <br />■ ANSI/APSP/ICC 3-2014, Standard for Permanently <br />Installed Residential Spas and Swim Spas <br />■ IAPMO/ANSI Z124.7-2013(R18), Prefabricated Plastic <br />Spa Shells <br />■ AC274, ICC-ES Acceptance Criteria for In -ground <br />Residential, Fiber -reinforced Plastic Swimming Pools and <br />Permanently Installed Plastic Spas, dated December 2006 <br />(editoriallyrevised July 2017) <br />ESR-2014 <br />Effective Date: November 2021 <br />This listing is subject to re-examination in one year. <br />A Subsidiary of the Intemational Code Council <br />2.0 USES <br />The fiberglass pool and spa shells are for recreational use <br />as swimming pools or spas in residential applications with <br />water circulated through a filter in a closed system. The <br />pools comply with ANSI/APSP/ICC-5 as Type O or Type I <br />pools. The spas comply with ANSI/APSP/ICC-3 and <br />IAPMO/ANSI Z124.7. <br />3.0 DESCRIPTION <br />3.1 General: <br />The fiberglass pool and spa shells consist of one-piece <br />fiberglass construction shop- formed over a mold. The <br />material is minimum 1/4-inch-thick (6.4 mm), fiberglass - <br />reinforced plastic (FRP), composed of isophtalic resin, <br />vinylester resin, fiberglass, and ceramic (ceramic in Viking <br />Pools only). The surface finish is a neopentyl glycol gel <br />coat. <br />The overall dimensions, depths and capacities are <br />shown in Table 1 for pools, Table 2 for spas and Table 3 <br />for models that are perrritted to be installed up to <br />191/2 i n ch es (495 mm) aboveground. <br />Notice: The pool and spa shells are designed to remain <br />full of water at all times. The shell may be damaged if the <br />water level is allowed to drop below the skimmer. When <br />appreciable drawdown is noticed or if it becomes <br />necessary to drain the pool or spa, contact Latham Pool <br />Products Inc., or its dealers for instructions. <br />3.2 Aboveground Pools and Spas: <br />Models intended for installation up to 191/2 inches <br />(495 mm) above ground, listed in Table 3, have vertical <br />supports consisting of 1-inch-by-11/2-inch-by-36-inch-long <br />(25 mm by 38 mm by 914 mm), Douglas fir, No. 2 mod <br />members encapsulated in the FRP process at 41/rfoot <br />(13372 mm) intervals. <br />4.0 INSTALLATION <br />4.1 General: <br />The swimming pool and spa shells must be permanently <br />installed in -ground or, in the case of the models shown in <br />Table 3, up to 191/2 inches (495 mm) above ground. All <br />plumbing and electrical installations must comply with the <br />relevant codes in effect at the construction site at the time <br />of construction. <br />Subject to the code official's approval, the pool or spa <br />shells may be installed without a soil investigation by a <br />registered design professional, provided none of the <br />following conditions is encountered atthe site: <br />1. The existence of groundwater wilhin the excavation, <br />where the pool or spa floor will contact the soil at the <br />time of installation. <br />Listings are not to be construed as representing aesthetic or any other attribraes not speafimLly addressed, nor are they to be con.wrual as an <br />endorsement of the subject ofthe listing or a recommendation for its use. There ism warranty by 1CCEwheation Service. LLC, express rw implied, a� to <br />an y fi nd rig or other mailer in this listing, or as to any product covered by the listing. <br />Copyright© 2021 ICC Evaluation Service, LLC. All rights reserved. <br />ll 5 <br />a�AAm <br />gas v <br />Page 1 of 5 <br />