My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST KAISER PERMANENTE 2025-05-12
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
2930 MAPLE ST KAISER PERMANENTE 2025-05-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2025 8:59:13 AM
Creation date
3/7/2025 2:47:49 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Tenant Name
KAISER PERMANENTE
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1542
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KAISER PERMANENTE Site Prep #1 Electrical Service <br />ASC & Clinic (HUB) March 18, 2020 <br />Everett, WA Project No. 19.05002.00 <br />Seismic Use <br />Group <br />Occupancy <br />Category <br />Nature of Occupancy <br />Importance <br />Factor <br />colleges or adult education facilities. <br />*Health care facilities with an occupant load of 50 or more resident <br />patients but not having surgery or emergency treatment facilities. <br />*Jails and detention facilities. <br />*Any other occupancy with an occupant load greater than 5,000. <br />*Power -generating stations, water treatment for portable water, waste <br />water treatment facilities and other public utility facilities not included in <br />Category IV. <br />*Buildings and other structures not included in Category IV containing <br />sufficient quantities of toxic or explosive substances to be dangerous <br />to the public if released. <br />Buildings and other structures designed as essential facilities including, <br />but not limited to: <br />*Hospitals and other health care facilities having surgery or emergency <br />treatment facilities. <br />*Fire, rescue and police stations and emergency vehicle garages. <br />*Designed earthquake, hurricane or other emergency shelters. <br />*Designed emergency preparedness, communication, operation <br />centers and other facilities required for emergency response. <br />*Power -generating stations and other public utility facilities required as <br />III <br />IV <br />emergency backup facilities for Category IV structures. <br />1.5 <br />*Structures containing highly toxic materials as defined by Section 307 <br />where the quantity of the material exceeds the maximum allowable <br />quantities of Table 307.7(2). <br />*Aviation control towers, air traffic control centers and emergency <br />aircraft hangars. <br />*Buildings and other structures having critical national defense <br />functions. <br />*Water treatment facilities required to maintain water pressure for fire <br />suppression. <br />Ip= 1.5 life safety component required to function after an earthquake (e.g. fire protection, smoke <br />control, etc.). Equipment or piping, ductwork that would imped egree from building. <br />Ip= 1.5 component that contains hazardous content <br />Ip= 1.0 all other components <br />For structures in Seismic Use Group III: <br />Ip= 1.5 all components needed for continued operation of the facility or whose failure could impair the <br />continued operation of the facility. <br />END OF SECTION 23 05 48 <br />VIBRATION AND SEISMIC CONTROLS FOR MECHANICAL PIPING AND 23 05 48 - 11 <br />EQUIPMENT <br />
The URL can be used to link to this page
Your browser does not support the video tag.