My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1622 W MUKILTEO BLVD 2025-03-10
>
Address Records
>
W MUKILTEO BLVD
>
1622
>
1622 W MUKILTEO BLVD 2025-03-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2025 11:15:57 AM
Creation date
3/10/2025 11:14:57 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
1622
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
it F O R T E 1213:3 MEMBER REPORT PASSED <br /> Level, Roof: Drop Beam <br /> 1 piece(s)4 x 8 Hem-Fir No.2 <br /> Overall Length:4'7' <br /> 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual tL Location Allowed Result LDF Load:Combination(Pattern) System:Roof <br /> Member Reaction(Ibs) 656©2" 4961(3.50") Passed(13%) -- 1.0 D+1.0 S(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(lbs) 400©10 3/4" 2918 Passed(14%) 1.15 1.0 D+1.0 5(All Spans) Building Code:IBC 2015 <br /> Moment(Ft-lbs) 647 @ 2'3 1/2" 3247 Passed(20%) 1.15 1.0 D+1.0 S(All Spans) Design Methodology:ASD <br /> Live Load Dell.(in) 0.009 @ 2'3 1/2" 0.213 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) Member Pitch:0/12 <br /> Total Load Defl.(in) 0.015 @ 2'3 1/2" 0.283 Passed(L/999+) -- 1.0 D+1.0 S(All Spans) <br /> •Deflection criteria:LL(L/240)and TL(L/180). <br /> •Top Edge Bracing(Lu):Top compression edge must be braced at 4'7"o/c based on loads applied,unless detailed otherwise. <br /> • Bottom Edge Bracing(Lu):Bottom compression edge must be braced at 4'7"o/c based on loads applied,unless detailed otherwise. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Snow Total Accessories <br /> • <br /> 1-Stud wall-HF 3.50" 3.50" 1.50" 255 401 656 Blocking <br /> 2-Column-HF 3.50" 3.50" 1.50" 255 401 656 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Dead Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 4'7" N/A 6.4 -- <br /> 1-Uniform(PSF) 0 to 4'7"(Top) 7' 15.0 25.0 Default Load <br /> Member Notes <br /> small ridge <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator lob Notes 6/23/2020 9:08:48 PM UTC <br /> Ruth Gonzales Exterior Porcha nd roof addition <br /> Gonzales Design Partners ForteWEB v2.4, Engine:V8.0.1.5,Data:V7.3.2.0 <br /> (425)344-9942 <br /> GonzalesoesignPartners©hotmail.com Weyerhaeuser File Name: Ryan-Lewis <br /> Page 5/9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.