Laserfiche WebLink
• <br /> PROJECT NAME: HULTS RESIDENCE ADDITION <br /> JOB: X10-2854 <br /> Grid Line Length Height 2L/H <br /> A 8.23' 8.00' 2.06 <br /> B 5.50' 8.00' 1.38 <br /> Sum 3.43 <br /> There are 3.43 bays < 4 req'd, therefore NOT OK <br /> Condition B, FAILED <br /> *** Direction 2 *** <br /> Check condition A <br /> Grid Line 2, Height = 8.00 ft <br /> Length Height/Length <br /> 1 8.58' 0.93 <br /> Total shear wall length = 8.6 ft <br /> Check shear wall piers that have h/L > 1.0. Remove that pier and check the length of removed pier ratio to <br /> total shear wall length is less than 0.33. <br /> Removed <br /> Grid/Pier Length Length/Total Length <br /> Condition A, PASSED <br /> Check condition B <br /> Grid Line Length Height 2L/H <br /> 2 8.58' 8.00' 2.15 <br /> Sum 2.15 <br /> There are 2.15 bays < 4 req'd, therefore NOT OK <br /> Condition B, FAILED <br /> CUSTOM DESIGN & ENGINEERING, INC. <br /> March 3, 2022 Page 16/67 <br /> Copyright©2022 Custom Design&Engineering,Inc.All rights reserved. <br />