Laserfiche WebLink
FASTENMASTER TECHNICAL BULLETIN FASTENMASTER TECHNICAL BULLETIN <br /> CONDITION 7—INTERIOR MOUNTED 4X4 POST TO 2X RIM WITH BLOCKING <br /> For this condition,use the DECK RAIL POST TO RIM BOARD <br /> 8"ThruLOK fastener <br /> 1.Install first screw in the center of the CONNECTION DETAILS <br /> post and 2"(+/-1/4")from the top of <br /> —--'__� _' the rim board <br /> ' According to the 2009 International Residential Code for One and Two-Family Dwellings,Table R301.5(ICC,2009), <br /> Q� I 2.Install second screw 1"in from the edge guardrails and handrails must be designed to withstand a single concentrated load of 200 pounds in any direction.A <br /> 1 of the post and 2"(+/•1/4")from the critical part of this connection is making a strong connection between the guardrail post and the rim board of the deck. <br /> 0 bottom of the rim board <br /> © <br /> O In most cases,a 1/2"through-bolt or carriage bolt is used to make this connection.When installed as instructed in this <br /> j `1 3.Install third screw 1"in from the other <br /> edge of the post and 3"(+/-1/4") bulletin,the ThruLOK System can replace 1/2"bolts,meeting the 200 pound design load for this part of the connection. <br /> from the bottom of the rim board <br /> APPLICATIONS <br /> iip <br /> CONDITION 8—INTERIOR MOUNTED 4X4 POST TO 2X RIM WITH SIDE BLOCKING ThruLOIC <br /> Screw Rolf Fostervng Sysr"n'. <br /> For this condition,use two,6 1/4" <br /> ' and one,8"ThruLOK fasteners <br /> 1.Install first 61/4"screw 1"in from the --' wit <br /> ----________ i �� edge of the post and 2"(+/-1/4") Q T <br /> - - ---= from the tap of the rim board ,L- <br /> JO © 2.Install second 6 1/4"screw 1"in from <br /> the other edge of the post and 2" <br /> c z7 (+/-1/4")from the bottom of the <br /> 0 rim board <br /> 3.Install 8"screw centered on both the DECK POST TO SINGLE RIM JOIST DECK POST TO DOUBLE RIM OR <br /> post and the rim board SINGLE RIM WITH BLOCKING <br /> INSTALLATION INSTRUCTIONS <br /> GENERAL FASTENING GUIDELINES 1.Choose the correct length(6 1/4"or 8")and fastening 6.Return to driving the screw in the <br /> Design values used to create the fastening patterns in this International Residential Code®(R319.3)and 2009 IRC pattern for each post to rim application based on the remaining 1/4"to 1/8"until thell <br /> bulletin were derived from individual fastener testing under (R317.1.3)for use in ACO pressure treated wood. illustrated conditions. washer and nut are firmly drawn <br /> ICC Acceptance Criteria AC233 and reported in ICC-ES Evaluationtogether. l�};"line <br /> As with other bolted connections using wet treated wood,the 2.Mark the sudace of the wood with the correct pattern. W <br /> Report ESR#1078.Full scale testing of the deck rail post to nut should be inspected and tightened'd needed after initial 7.Make sure that the point of the <br /> deck frame connections were also conducted by an accredited drying 3.If a flush mounted head is required,use a 1 1/4"spade bit <br /> third party to support these details. period. to create a 1/4"deep recess in the rim or post. ThruLOK fastener has passed the Ili • <br /> The connection details in this bulletin ore an acceptable means "MIN LINE"printed on the nut. <br /> The connection details shown in this bulletin apply specifically 4.Remove the pre assembled eed/hK nut from the screw and I <br /> of transferring the load from guard post to rim joist only. using a 1/2"drill on low speed/high torque setfing,install 8.Repeat until all of the fasteners are <br /> to 4x4 posts and 2x8,2x10 or 2x12 rims and/or joists. Additional blocking or hardware may be required to transfer installed correctly according to the <br /> the ThruLOK screw and washer into the outside fore of the <br /> For different dimension lumber,wood species of lower density loads from the rim to deck joists. application until the screw is 1/4"to 1/8"from being flush. specifications contained in this bulletin. <br /> than Hem Fir(SYP and DF are higher density and therefore Fastening patterns assume the following:All components ore <br /> approved),or post heights greater than 37.5"off the top of used(screw,washer and nut),holes are not pre-drilled,and S.Thread the ThruLOK nut onto the exposed threaded end of <br /> the joists,please contact FastenMaster to determine the proper posts are loaded in an outward direction from the deck. the fastener.Firmly wilt on the nut by hand until snug. ' <br /> fastening solution. <br /> For questions regarding these or other connections,please contact <br /> ThruLOK is coated with mechanically applied zinc in accordance FastenMaster Technical Support at www.fastenmaster.com or by g Effective until Decmber 31,2014.Updated information must be obtained after this dote. <br /> with ASTM 6695,Class 55.This is compliant with the 2006 calling 800.5183569. 0 FastenMaster. <br /> FASTER EASIER STRONGER 153 BOWLES ROAD,AGAWAM,MA 01001 413.789.0252 800-518.3569 WWW.FASTENMASTER.COM <br /> FostenMoster'and thrulOK°are trademarks of OMG,Inc. <br /> copyrght®2014 OMG,Inc All rights reserved. <br />