Laserfiche WebLink
95 <br /> 1�lGE�`' ` T 402I5 827.7 98033 <br /> 850 <br /> ARCIIITICTS ► 1 <br /> www.oadeandbeard.com <br /> February 21, 2020 <br /> Drew Martin <br /> Associate Engineer—Commercial Plans Examiner <br /> City of Everett Permit Services <br /> 3200 Cedar Street, 2nd Floor <br /> Everett, WA 98201 <br /> RE: Plan Check No. B2002-028 <br /> Project: Birdwell Machine Tenant Improvement <br /> Project Address: 1420 80th ST SW, SUITE D <br /> Dear Drew, <br /> In accordance with the 2015 IEBC, Section 705,the following items are currently compliant with <br /> the 2009 ICC A117.1: <br /> • Clear floor space and turning spaces exist in all rooms. <br /> • Men's and women's restrooms are fully compliant with Chapter 6 of the 2009 ICC <br /> A117.1. <br /> o Clear floor spaces have been verified as compliant for both toilets and sinks. <br /> o Horizontal and vertical grab bars have been verified to be in the correct <br /> locations. <br /> o Under sink knee clearance is compliant. <br /> o Exposed plumbing has been covered. <br /> o Fixture heights and locations have been verified to be compliant. <br /> In accordance with the 2015 IEBC, Section 705 we have proposed the following improvements <br /> as part of this tenant improvement: <br /> • Addition of three accessible parking spaces (one van accessible) with access aisles. <br /> The accessibility deficiencies related to this permit will not cause a breach in the 20%threshold <br /> per IEBC 705.2.1. <br /> Thank you, <br /> Galen Page, PresidentError! Bookmark not defined. <br /> Page and Beard Architects, P.S. <br /> 425-827-7850 <br /> Page 1 of 1 <br />