My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1420 80TH ST SW D BIRDWELL MACHINE 2025-03-11
>
Address Records
>
80TH ST SW
>
1420
>
BIRDWELL MACHINE
>
1420 80TH ST SW D BIRDWELL MACHINE 2025-03-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2025 9:36:03 AM
Creation date
3/11/2025 9:34:27 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1420
Unit
D
Tenant Name
BIRDWELL MACHINE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
75) <br /> 4. Wiring <br /> 1)As shown in the illustration, insert the wires including the ground wire into the conduit and secure them with lock nut onto <br /> the conduit mounting plate. <br /> 2) Strip wire ends(3/4 inch (2Omm)). <br /> 3) Match wire colours with terminal numbers on the terminal block of indoor and outdoor unit and firmly secure the wires in <br /> the corresponding terminals with screws. <br /> 4) Connect the ground wire to the corresponding terminals. <br /> 5) Pull the wires lightly to make sure they are securely connected. <br /> 6)While close the service lid,shape the wires so that the service lid fits securely,then close the service lid. <br /> I_l':iil_Il I Terminal block Firmly fix the wires with the terminal screws. <br /> Outdoor unit <br /> Electrical <br /> i• wiring box <br /> q(1 Use AWG16 if the connection wire <br /> �, tit 1 ■ ■■■. ■ Shape wires so that the length is less than 33ft 10m,or ... <br /> E <br /> ISa .� service lid fits securely. AWG14 if it is 33ft(tOm)or more, If <br /> )U+IIIII <br /> ■ <br /> Wire retainer <br /> L�.1,__ _ ■!11 Use the specified wire type. t <br /> ' t. Indoor 2•:I■ <br /> --�\ unit 3•■ IN <br /> Back O <br /> / Firmly fix the wires with <br /> - Conduit mounting plate the terminal screws. <br /> Conduit Lock nut <br /> A WARNING <br /> • Do not use tapped wires, extension cords,or starburst connections,as they may cause overheating, electric shock,or fire. <br /> • Do not use locally purchased electrical parts inside the product.(Do not branch the power for the drain pump,etc.,from the <br /> terminal block.) Doing so may cause electric shock or fire. <br /> • Do not connect the power wire to the indoor unit.Doing so may cause electric shock or fire. <br /> 5. Drain piping <br /> 1) Connect the drain hose, as described on the right. The drain hose should <br /> be inclined downward. <br /> No trap is permitted. <br /> Do not put the end <br /> /of the hose in water. <br /> 2) Remove the air filters and pour some water into the drain pan to check the <br /> water flows smoothly. <br /> E <br /> 3) If drain hose extension or embedded drain piping is required, use appropriate <br /> parts that match the hose front end. <br /> Figure of hose front end <br /> 4) When extending the drain hose, use a commercially available E E <br /> extension hose with an inner diameter of 5/8 inch (16mm). <br /> Be sure to thermally insulate the indoor section of the Indoor unit Extension drain hose <br /> extension hose. a drain hose <br /> Drain hose supplied Heat insulation tube <br /> ��/� with the indoor unit (field supply) <br /> ■English 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.