My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1420 80TH ST SW D BIRDWELL MACHINE 2025-03-11
>
Address Records
>
80TH ST SW
>
1420
>
BIRDWELL MACHINE
>
1420 80TH ST SW D BIRDWELL MACHINE 2025-03-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2025 9:36:03 AM
Creation date
3/11/2025 9:34:27 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1420
Unit
D
Tenant Name
BIRDWELL MACHINE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• .c <br /> 2. Drain work (only for heat pump 09/12class 15/18/24 class w <br /> ©Drai <br /> n cap(1) ©Drain cap(1) <br /> models, excluding RXL models) ©Draincap(2) /1 @Drain cap(2) <br /> CAUTION �.,u <br /> In cold areas,do not use a drain socket, drain caps(1,2) c .©Drain cap(1) <br /> o ©Drain o--� <br /> and a drain hose with the outdoor unit.(Drain water may@Drain side socket Drain cap2 <br /> socket Air outlet Air outlet side © ( ) <br /> freeze, impairing heating performance.) Q <br /> • If the drain port is covered by a mounting base or floor Bottom frame <br /> surface, place additional foot bases of at least 1-1/4 Drain cap <br /> _I vriA���� Bottom frame <br /> inch (30mm)in height under the outdoor unit's feet. <br /> @Drain socket <br /> 1)Attach©drain cap(1)and 0drain cap(2). Pi�the bottom <br /> 2)Attach©drain socket. frame in. Hose(availabl(comm)jrcially,� <br /> inner dia.5/8" 16mm <br /> • When attaching©drain socket to the bottom <br /> frame, make sure to connect the drain hose to the <br /> drain socket first. <br /> Check <br /> 3. Flaring the pipe end The flare's The pbe evv pe nlyendmunt <br /> ent flared in <br /> inner surface a perfect circle. <br /> must be <br /> 1)Cut the pipe end with a pipe cutter. flaw-free. snake sure that the <br /> flare nut is fitted. <br /> 2) Remove burrs with the cut surface facing Cut exactly at/ \ <br /> right angles. Remove burrs. <br /> downward,so that the filings do not enter the <br /> pipe. Flaring <br /> 3) Put the flare nut on the pipe. Set exactly at the position shown below. <br /> 4) Flare the pipe. \ Flare tool for R410A Conventional flare tool <br /> Clutch-type Clutch-type(Rigid-type)Wing-nut type(Imperial-type) <br /> 5) Check that the flaring has been done correctly. i 0-0.020 inch 0.039-0.059 inch 0.059-0.079 inch <br /> Die A ( <br /> (0-0.5mm) 1.0-1.5mm) (1.5-2.0mm) <br /> WARNING <br /> • Do not apply mineral oil to the flare. <br /> • Prevent mineral oil from getting into the system as this would reduce the service life of the units. <br /> • Never use piping which has been used for previous installations.Only use parts which are delivered with this unit. <br /> • Never install a dryer to this R410A unit in order to guarantee its service life. <br /> • The drying material may dissolve and damage the system. <br /> • Incomplete flaring may result in refrigerant gas leakage. <br /> 4. Refrigerant piping <br /> A CAUTION <br /> • Use the flare nut fixed to the main unit.(This is to prevent the flare nut from cracking as a result of deterioration over time.) <br /> • To prevent gas leakage,apply refrigeration oil only to the inner surface of the flare.(Use refrigeration oil for R410A.) <br /> • Use a torque wrench when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. <br /> • Align the centers of both flares and tighten the flare nuts 3 or 4 turns by hand,then tighten them fully with a spanner and a <br /> torque wrench. <br /> Flare nut tightening torque Apply oil <br /> Gas side Liquid side <br /> A3/8 inch(9.5mm) 1/2 inch(12.7mm) 5/8 inch(15.9mm) 1/4 inch(6.4mm) Do not apply refrigeration oil <br /> to o refrigeration <br /> oil to the inner <br /> r surface.t to the outer 24-1/8-29-1/2ft•lbf 36-1/2-44-1/2ft•lbf 45-5/8-55-5/8ft•lbf 10-1/2-12-3/4ft•lbf oil —- surface of the flare. <br /> (32.7-39.9N•m) (49.5-60.3N•m) (61.8 75.4N•m) (14.2-17.2 N•m) Flare nut <br /> Width across flats 11/16 inch(17mm) 3/4 inch(19mm) 7/8 inch(22mm) 1-1/16 inch(27mm) <br /> Valve cap 10-1/2-12-5/8ft•Ibf 12-5/8-15-3/8ft•lbf 16-20-1/4ft•lbf 35-3/8-44-1/8ft•lbf <br /> tightening torque (14.2-17.2N•m) , (17.1-20.9N•m) (21.6-27.4N•m) (48-59.8N•m) <br /> Do not apply refrigeration oil to <br /> Service port cap tightening torque the flare nut to avoid tightening <br /> with excessive torque. <br /> 8-10-7/8ft•lbf(10.8-14.7N•m) <br /> •English 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.