Wiring <br /> 0 WARNING <br /> • Do not use tapped wires,extension cords,or starburst connections,as they may cause overheating,electric shock,or fire. <br /> • Do not use locally purchased electrical parts inside the product.(Do not branch the power for the drain pump,etc.,from the <br /> terminal block.) Doing so may cause electric shock or fire. <br /> • Be sure to install a ground fault circuit interrupter.(One that can handle higher harmonics.) <br /> (This unit uses an inverter.Therefore,a ground fault circuit interrupter capable of handling higher harmonics must be used in <br /> order to prevent the ground fault circuit interrupter malfunctioning.) <br /> • Use an all-pole disconnection type circuit breaker with at least 1/8 inch (3mm)between the contact point gaps. <br /> • When carrying out wiring,take care not to pull at the conduit. <br /> • Do not connect the power wire to the indoor unit.Doing so may cause electric shock or fire. <br /> • Do not turn on the circuit breaker until all work is completed. • <br /> 1) Strip the insulation from the wire(3/4 inch(20mm)). <br /> 2)Connect the inter-unit wires between the indoor and outdoor units so that the terminal numbers match.Tighten the <br /> terminal screws securely.It is recommended that a flathead screwdriver be used to tighten the screws. <br /> The screws are packed with the terminal block. <br /> Firmly fix the wires with <br /> the terminal screws. Outdoor unit <br /> Use AWG16 if the connection wire \�::A gs] <br /> length is less than 33ft(10m),or Ill If <br /> AWG14 if it is 33ft(10m)or more. 1 Use AWG 14 wires. <br /> • <br /> ■ y <br /> Indoor 2• ■ <br /> 3• Circuit Ground fault Power supply <br /> unit Mt <br /> f) ■ breaker circuit interrupter 60Hz 208-230V <br /> Firmly fix the <br /> wires with the RX09/12*,RK09/12+ <br /> terminal screws. RXN09/12/18*,RKNO9/12/18*,RXL09/12/15* 15A <br /> Ground RX18/24*,RK18/24* 20A <br /> = RXN24*,RKN24+ <br /> 09/12 class <br /> [Method of mounting conduit] <br /> • A protection plate is fixed for protection from the high-voltage section. <br /> 1)Dismount the stop valve cover by removing the screw. <br /> 2)Dismount the protection plate by removing the 2 screws. <br /> 3)Dismount the conduit mounting cover by removing the 2 screws. <br /> 4)Pass wires through the conduit and secure them with a lock nut. <br /> 5)After completing the work, reattach the stop valve cover,the conduit mounting cover,and the protection plate to its <br /> original position. <br /> �11�=CIE Power supply Protection plate , <br /> 2 ® 3 O/ terminal block <br /> 0 © I <br /> I •• �3' Shape wires sor F 151 <br /> �' I '�\ <br /> �v� I i that the protection �'" _ ;;gj , <br /> L, • <br /> ' plate anonduit �r u �� , <br /> cover <br /> Conduit a Screws ' 1 <br /> mounting -� 1 1n1 <br /> !)i plate --- n,'IP�II t s, �� * <br /> / N.,((;A <br /> H <br /> Lock nut Conduit I I L I <br /> i <br /> 9 ■English <br />