Laserfiche WebLink
Region Regulatory compliance/quality marks <br />USA UL AMCX: Central Station Alarm Units <br />(UL1610,UL1635), APAW: Police Sta- <br />tion Alarm Units (UL365, UL464), <br />APOU: Proprietary Alarm Units <br />(UL1076), NBSX: Household Burglar <br />Alarm System Units (IL1023), UOJZ: <br />Control Units, System (UL864, 9th edi- <br />tion) <br />UL UL 864 - Standard for Control Units and <br />Accessories for Fire Alarm Systems <br />(10th edition) <br />UL UL 985 - Household Fire Warning Sys- <br />tem Units (6th edition) <br />CSFM California State Fire Marshal <br />FDNY- <br />6286 D7412GV4 D9412GV4 NYC COA <br />CoA <br />6286 2018-2021 <br />NYC- <br />12-92-E, Vol. 12 12-92-E, Vol. 12 <br />M EA <br />NYC- <br />12-92-E, Vol. XV <br />M EA <br />Compatibility Information <br />Category BroductI <br />Control Panels G-series' <br />B-series2 <br />D94123, D74123, D72123* <br />D91243 <br />Detectors For a list of compatible two wire detectors, refer <br />to the ApprovedApplications Compliance Guide <br />for the control panel being used. <br />Modules D8128D OctoPOPIT Eight -point Expander <br />Mounting D137 Mounting Bracket <br />Brackets <br />D138 Mounting Bracket, Right Angle <br />' G-series = D9412GV4, D7412GV4, D7212GV4', D9412GV3, <br />D7412GV3, D7212GV3', D9412GV2, D7412GV2, D7212GV2', <br />D9412G3, D7412G3, D7212G3' <br />2 B series = B5512 and B4512 <br />3 These products are legacy products and have been investigated for <br />compatibility only to UL864 8th edition <br />' The D7212 models are not listed for commercial fire applications <br />Notification Appliances <br />Notification appliances used with the D192G Module <br />must: <br />• Be polarized (DC) equipment <br />• Match the voltage rating of the alarm power supply <br />• Not exceed the current rating of the alarm power <br />supply <br />• Not exceed 3.0 A in combined device current for each <br />D192G Module <br />Wiring <br />Use a Class B, Style W, two -wire circuit and wire <br />according to the instructions supplied with the <br />module. No more than twelve D192G modules can be <br />used per system. For UL applications, a listed (UTRZ) <br />regulated power supply can be used to power <br />notification devices through the D192G module. <br />To comply with NFPA Standards: <br />• The control panel and power supply must be <br />supervised or installed in the same room not more <br />than 20 ft (6 m) from the module <br />• Wiring between the control panel and the power <br />supply must be in conduit <br />• Power supply fault conditions must be supervised by <br />a UL Listed relay <br />Quan Component <br />tity <br />1 NAC module <br />1 Hardware pack <br />1 L Literature pack Ap" <br />Electrical <br />External Power In <br />Current: 3.0 A maximum <br />Voltage: 12 VDC or 24 VDC nominal <br />Aux Power In <br />Current: 100 mA maximum <br />Voltage: 12 VDC nominal <br />Supervisory Zone Control <br />Current: 5 mA maximum <br />Mechanical <br />Dimensions: 5 in. x 3 in. x 0.75 in. (13 cm x 8 cm x 2 cm) <br />D192G Notification appliance module <br />The D192G Notification Appliance Circuit (NAC) <br />module is used for wiring connections to remote <br />signaling devices. The wiring is supervised for open, <br />short, or grounded circuit faults. Either 12 VDC or <br />24 VDC notification devices can be used depending on <br />the choice of power supply. <br />Order number D192G <br />