Region Regulatory compliance/quality marks <br />Wiring Considerations <br />FM <br />Wire Size Maximum Length of all Data <br />Expansion Loops Combined <br />CSFM California State Fire Marshal <br />0.8 mm (22 AWG) 549 m (1800 ft) <br />FDNY- 6059 [D9412GV3 & D7412GV31 <br />CoA <br />1.0 mm (20 AWG) 881 m (2890 ft) <br />FDNY- 6286 D7412GV4 D9412GV4 NYC COA <br />1.2 mm (18 AWG) 1402 m (4600 ft) <br />CoA 6286 2018-2021 <br />FDNY- 6196 <br />1.5 mm (16 AWG) 2231 m (7320 ft) <br />CoA <br />1.8 mm (14AWG) 3551 m (11650ft) <br />Australia CTICK C-Tick <br />D8125 or B299 POPIT Loops <br />Canada ULC CAN/ULC S304- Standard for Signal Re- <br />Use one two -wire data expansion loop, or distribute <br />a mgCenterandPremiseBurglar Alarm <br />Alarm <br />the POPITs on multiple loops. The maximum lengths <br />shown in the following table are for all data expansion <br />ULC S303-Local Burglar AlarmUnitsand <br />loops combined connected to the same D8125 or <br />Systems <br />B299 module. Setting DIP switches on the POPIT <br />ULC ULC 365- Police Station Connected Bur- <br />modules assigns them to point numbers. The switch <br />glar Alarm Units <br />setting on each POPIT assigns it a point number, <br />ULC APOU7.S1871 Proprietary Alarm Units <br />regardless of its physical location. <br />Certified for Canada <br />POPIT to Sensor Loops <br />ULC ULC-ORD C1023 - Household Burglar <br />The number of detection devices each sensor loop can <br />Alarm System Units <br />supervise is limited only by the resistance on the loop. <br />Resistance on each sensor loop must be less than <br />Instal ' igu ration notes100 <br />0 not including the end -of -line (EOL) resistor. <br />Compatibility Information <br />Certain UL and National Fire Protection Association <br />(NFPA) applications can limit the number of detection <br />Control Panels All G Series control panels, D9412, D7412, <br />devices. Consult the appropriate UL or NFPA <br />D7212, D7212131, D9112, D911261, <br />standards. <br />D8112G1, D8112G2, and D9124 <br />Terminate each POPIT sensor loop with the 33 kid EOL <br />Modules D8125,6299 <br />resistor included with each POPIT. <br />Use a twisted -pair wire (six twists per foot) in all <br />The D8125 or B299 POPEX Modules are required. The <br />POPIT installations for both the data expansion loop <br />D9127 modules are wired in parallel on the D8125 or <br />wiring and the POPIT sensor loops. Run wires away <br />B299 data loops. <br />from AC sources to prevent AC induction. <br />Number of POPIT Modules per Control Panel <br />D7212G, D7212GV2, D7212GV3 32 D9127 POPITs Environmental Considerations <br />D7212B1 40 D9127 POPITs <br />Relative humidity Up to 93%nnn-condensing <br />D7212, D7412, D7412G, D7412GV2, 67 D9127 POPITs Temperature 0°C to +60°C (+32°F to +140°F) <br />D7412GV3,D7412GV4 <br />(operating) For ULCertifcated Installations, CCto+SAC <br />D9124 119 D9127 POPITs (+32Fto +12,10 <br />D9112131 126 D9127 POPITs Properties <br />D9112, D9412, D9412G, D9412GV2, 238 D9127 POPITs Color Off white <br />D9412GV3,D9412GV4 <br />B8512G (D8125) 67 D9127 POPITs Dimensions 8.1 cm x 3.8 cm x 2.4 cm <br />(3.2 in. x 1.5 in. x 0.9 in.) <br />B8512G (B299) 91 D9127 POPITs <br />Material UL Listed fire-resistant <br />B9512G (D8125) 238 D9127 POPITs <br />B9512G (B299) 591 D9127 POPITs <br />