Specifications <br />Agency Listings and Approvals <br />PHYSICAL SPECIFICATIONS: <br />pull station <br />SB-1/0 <br />SB-10 <br />Height <br />5.5 inches <br />5.601 inches <br />5.5 inches <br />(13.97 cm) <br />(14.23 cm) <br />(13.97 cm) <br />Width <br />4.121 inches <br />4.222 inches <br />4.121 inches <br />(10.47 cm) <br />(10.72 cm) <br />(10.47 cm) <br />Depth <br />1.39 inches <br />1.439 inches <br />1.375 inches <br />(3.53 cm) <br />(3.66 cm) <br />(3.49 cm) <br />52004dim.tbl <br />ELECTRICAL SPECIFICATIONS: <br />Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC or <br />VDC. <br />ENGINEERING/ARCHITECTURAL SPECIFICATIONS <br />Manual Fire Alarm Stations shall be non -code, with a key- or <br />hex -operated reset lock in order that they may be tested, and so <br />designed that after actual Emergency Operation, they cannot be <br />restored to normal except by use of a key or hex. An operated <br />station shall automatically condition itself so as to be visually <br />detected as activated. Manual stations shall be constructed of <br />red colored LEXAN (or polycarbonate equivalent) with clearly <br />visible operating instructions provided on the cover. The word <br />FIRE shall appear on the front of the stations in white letters, <br />1.00 inches (2.54 cm) or larger. Stations shall be suitable for <br />surface mounting on matching backbox SB-10 or SB-I/O; or <br />semi -flush mounting on a standard single -gang, double -gang, or <br />4" (10.16 cm) square electrical box, and shall be installed within <br />the limits defined by the Americans with Disabilities Act (ADA) or <br />per national/local requirements. Manual Stations shall be Under- <br />writers Laboratories listed. <br />NOTE: *The words "FIRE/FUEGO" on the B0-12LSP shall appear <br />on the front of the station in white letters, approximately 314" <br />(1.905 cm) high. <br />The listings and approvals below apply to the BG-12 Series pull <br />stations. In some cases, certain modules may not be listed by <br />certain approval agencies, or listing may be in process. Consult <br />factory for latest listing status. <br />• C(UL)US: S711 <br />• FM Approved <br />• CSFM:7150-0075:184 <br />• MEA:67-02-E <br />• Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; <br />6,632,108. <br />Product Line Information <br />BG-12S: Single-action pull station with pigtail connections, hex <br />lock. <br />BG-12SL: Same as BG-12 with key lock. <br />BG-12: Dual -action pull station with SPST N/O switch, screw <br />terminal connections, hex lock. <br />BG-12L: Same as BG-12 with key lock. <br />BG-12LSP: Same as BG-12L with English/Spanish (FIRE/ <br />FUEGO) labeling. <br />BG-12LOB: Same as BG-12L with `outdoor use" listing. <br />Includes outdoor listed backbox, and sealing gasket. <br />BG-12LO: Same as BG-12L with "outdoor use" listing. Does <br />not include backbox. <br />BG-12LA: Same as BG-12L with auxiliary contacts. <br />BG-12LPS: Dual -action pull station with pre -signal option. <br />BG-12LPSP: Same as BG-12LPS with English/Spanish (FIRE/ <br />FUEGO) labeling. <br />SB-10: Surface -mount backbox, metal. <br />SB-1/0: Surface -mount backbox, plastic. (Included with 13G- <br />12LOB.) <br />BG12TR: Optional trim ring for semi -flush mounting. <br />17003: Keys, set of two. (Included with key -lock pull stations.) <br />17007: Hex lock, 9/64". (Included with hex -lock pull stations.) <br />NOTE: For addressable BG-12LX models, see data sheet DF- <br />52013. <br />Fire•LiteO Alarms, SpectrAlert® Advance, and System Sensor® are <br />registered trademarks of Honeywell International Inc. <br />02008 by Honeywell International Inc. All rights reserved. Unauthorized use <br />of this document is strictly prohibited. <br />I�O 9001 This document is not intended to be used for installation purposes. <br />We try to keep our product information up-to-date and accurate. <br />We cannot cover all specific applications or anticipate all requirements. <br />ENGINEERING & MANUFACTURING All specifications are subject to change without notice. <br />QUALITY SYSTEMS Made in the U.S. A. <br />For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. <br />www.firelite.com <br />Page 2 of 2 — DF-52004:A1 •04/22/08 <br />