Project'Title: Bement B3/16 <br /> Engineer: <br /> Project ID:. <br /> Project Descr: <br /> Printed: 6 AUG 2021,12:19PM <br /> Wood Beam Software <br /> Software copyright ENERCALC,INC.19832120,Build:12.26.8.24 <br /> Lilo.0:KW-06010288 RB Engineers,Inc. <br /> DESCRIPTION: BM#1 <br /> Overall Maximum Deflections <br /> Load Combination Span Max="Deft Location In Span Load Combination Max"+"Dell Location in Span <br /> +D+L 1 0.3709 7.051 0.0000 0.000 <br /> Maximum Deflections for Load Combinations <br /> Load Combination Span Max.Downward Defl Location in Span Max.Upward Deft Location'r Sr <br /> D Only 1 0.1059 In 7.051 ft 0.0000 In 0.000 ft <br /> +D+L 1 0.3709 in 7,051 ft 0.0000 in 0.000 ft <br /> +D+0.750L 1 0.3046 in 7.051 ft 0.0000 In 0.000 ft <br /> +0.60D 1 0.0635 in 7.051 ft 0.0000 in 0.000 ft <br /> L Only 1 0.2651 in 7.051 ft 0.0000 In 0.000 ft <br /> Vertical Reactions Support notation:Far left is#1 Values in KIPS <br /> Load Combination Support 1 Support 2 <br /> Overall MAXimum 6.559 6.559 <br /> Overall MINimum 4.560 4.560 <br /> D Only 1.999 1.999 <br /> +D+L 6.559 6.559 <br /> +D+0.750L 5.419 5.419 <br /> +0.60D 1.199 1.199 <br /> L Only 4.560 4.560 <br /> 15 <br /> 11 . <br /> n <br /> II <br /> 7 <br /> u 7 <br /> u <br /> C <br /> N <br /> E <br /> 0 <br /> E 4 <br /> MEMBER•••» <br /> 1,33 2,71 4,03 5,47 6,85 8,23 9,61 10.59 12,36 13.74 <br /> Distance(ft) <br /> I DOnly I+D+l I+D+D.1S6t I+6.66D <br />