i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: M2406-051 Description: INTERIOR, BASEMENT,Replace furnace like and kind <br /> Applied:6/13/2024 Approved: 6/13/2024 Site Address: 1215 E CASINO RD <br /> Issued:6/14/2024 Finaled: City,State Zip Code: EVERETT,WA 98203 <br /> Status: PERMIT ISSUED-ONLINE Applicant: PARAGON HTG/(CONST)HM CRFT SLTNS LLC <br /> Parent Permit: B2112-040 Owner:WOLDE TESFAYE T/GEBREAMANUAEL ALEMTSEHAY <br /> Parent Project: Contractor: PARAGON HTG/(CONST)HM CRFT SLTNS LLC <br /> Details: <br /> Additional mechanical for adding 7 supply ducts to downstairs <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 6/20/2024 6/20/2024 MECH 04-ROUGH JASON CORRECTION see notes <br /> IN MORRISSEY REQUIRED <br /> Notes: <br /> 206-407-7215 Tsefaye Wolde <br /> -Provide make up air from the exterior via properly installed ducts for furnace and water heater per the IRC minimum 40 square inches cross sectional <br /> duct area per IRC G2407.6.2 One Permanent opening method. <br /> G2407.4(304.4)Makeup Air Provisions <br /> Where exhaust fans,clothes dryers and kitchen ventilation systems interfere with the operation of appliances,makeup air shall be provided. <br /> -Maintain 6"clearance to combustibles for single wall venting or switch to double wall b vent for 1"clearance to combustibles,(Furnace and Water <br /> Heater). <br /> 7/2/2024 7/2/2024 MECH 04-ROUGH JEFF M RHODE CORRECTION see notes <br /> IN REQUIRED <br /> Notes: <br /> 206-407-7215 Tsefaye Wolde <br /> JJM 6/20/2024 3:12:26 PM-Provide make up air from the exterior via properly installed ducts for furnace and water heater per the IRC minimum 40 <br /> square inches cross sectional duct area per IRC G2407.6.2 One Permanent opening method.G2407.4(304.4)Makeup Air ProvisionsWhere exhaust fans, <br /> clothes dryers and kitchen ventilation systems interfere with the operation of appliances,makeup air shall be provided.-Maintain 6%34 clearance to <br /> combustibles for single wall venting or switch to double wall b vent for 1%34 clearance to combustibles.'provide Btu load for appliances and <br /> calculations providing adequate combustion air through approved methods' <br /> 7/11/2024 7/11/2024 MECH 04-ROUGH JEFF M RHODE APPRVD-PERMIT <br /> IN FINAL <br /> Notes: <br /> 206-407-7215 Tsefaye Wolde <br /> jmr changed Inspection Type from GAS 01-ROUGH IN to MECH 04-ROUGH IN <br /> I <br /> Printed: Friday, 12 July,2024 1 of 1 rk <br /> SUPERION <br />