Laserfiche WebLink
GENERAL YES NO <br /> Bathroom doors are easily and quickly openable from the outside when locked 0 <br /> Carbon Monoxide alarms are installed as required in R315 on each level of the home. ❑ <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room, outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(R314). ❑ <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all 0 0 <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. El <br /> 13 <br /> R330.4 Operable parts of door handles, pulls, latches,locks and other devices installed in AFH shall be operable 1 14 ❑ <br /> with one hand and shall not require tight grasping, pinching or twisting of the wrist(lever-type). <br /> Pocket doors shall have graspable hardware available when in the closed or open position. 0 <br /> R311.8 RampA I YES NO <br /> Inside Ramp N/A © 0 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope). (Exception R311.8.1 Not allowed in j ❑ ❑ <br /> R330.9) <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where <br /> E3 El <br /> ramp changes directions. <br /> R330.9.1 Handrails required on both sides of ramp. 13 ❑ <br /> Outside Ramp I N/A U I YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope). (Exception R311.8.1 Not allowed in) ❑ ❑ <br /> R330.9) <br /> R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom,where doors open onto ramps,and where ❑ ❑ <br /> ramp changes directions. <br /> R330.9.1 Handrails required on both sides of ramp. O ❑ <br /> R312.1.1 Guards shall be located along open-sided walking surfaces,that are located more than 30 inches measured ❑ ❑ <br /> vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br /> Guards below are depicted vertically as an example only. <br /> I <br /> I <br /> i <br />( Handrail both sides <br /> Less than 4" 34"-38" <br /> r <br /> Guard - <br /> 36"min <br /> I <br /> It <br /> Tx 3'min <br /> iuu <br /> i landing <br /> G <br />` 3'x 3'min --------- <br /> Ianding <br /> — 3' --- -1 One unit vertical in twelve units horizontal 3' <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> i <br /> i <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br />