Construction-level documents should be submitted for review. Two complete sets of the drawings should be <br /> submitted. Preliminary comments are provided below to assist in preparing the drawings, but these are not <br /> intended to provide a comprehensive review. <br /> Comments: <br /> 1. Construction-level drawings should be submitted for review. The sketches including the structural calculations <br /> are not sufficient. <br /> 2. The project involves a multi-family building with more than 4 dwellings. The construction drawings must be <br /> prepared and sealed by a professional architect licensed in the state of Washington. See RWC Section <br /> 18.08.410 Item (5). <br /> 3. The drawings should include framing plans prepared and signed by a professional engineer licensed in the state <br /> of Washington. See RCW Sections 18.43.010, 18.43.020, and 18.43.070. <br /> 4. The drawings should specify the applicable building codes, including but not limited to the 2018 IBC and 2018 <br /> WSEC. <br /> 5. The Occupancy Classification should be specified in the drawings. <br /> 6. The Construction Type should be specified in the drawings. The required fire-rated performed required for <br /> components of the building system should be stated. <br /> 7. The drawing should state if existing sprinkler and fire alarms systems are present. <br /> 8. The architectural drawings should include repair of the fire-rated assemblies. Details for the assemblies should <br /> be included. The details should specify a listed tested assembly. <br /> 9. Smoke and CO alarms should be specified in the drawings. <br /> 10. The exterior envelope elements are required to comply with WSEC Chapter 5. <br /> Ej r-- Drew Martin, P.E.,S.E. <br /> Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> Phone Hours: M/W/T: 8 am -12 pm & 1 pm—3 pm;Tu: 1:00pm-3:OOpm <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> 7/17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.