My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 112TH ST SW BLDG A SAGE APARTMENTS 2025-04-07
>
Address Records
>
112TH ST SW
>
1730
>
SAGE APARTMENTS
>
1730 112TH ST SW BLDG A SAGE APARTMENTS 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 11:55:53 AM
Creation date
3/13/2025 2:50:48 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1730
Unit
BLDG A
Tenant Name
SAGE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Eaveguard°meets or exceeds requirements of <br /> ASTM D197O as outlined below. <br /> Physical properties <br /> R'"DERLA <br /> Surfacing Sand <br /> ® ENTHen Eaveguard providesComposition Modified-Asphalt Fiberglass <br /> Reinforced Membrane <br /> a secondary line of defense <br /> to keep water that can get Thickness,nominal 57 mils <br /> behind shingles from infiltrating Performance properties Requirement Test method <br /> further to help ensure the Maximum load, MD/XD Min.25lbf/in-width ASTM D2523 <br /> ASTM D1970 <br /> longevity of your roof. <br /> Elongation at break,MD/XD Min.10% ASTM D2523 <br /> ' -Modified-Asphalt Portion ASTM D1970 <br /> Tear resistance,MD/XD Min.20 Ibf ASTM D4073 <br /> ASTM D1970 <br /> Adhesion to plywood <br /> Why are self-adhered at 40°F Min.2 Ibf/ft-width ASTM 903 <br /> underlayments needed? at 75°F Min.12 Ibf/ft-width ASTM D1970 <br /> Nail sealability Pass ASTM D1970 <br /> Sloped roofs are designed to shed water. ASTM D7349 <br /> Underlayments provide waterproofing protection Low temperature flexibility Pass ASTM D1970 <br /> allowing for proper water flow while protecting Waterproofing Integrity after Pass ASTM D1970 <br /> low temperature flex <br /> Vulnerable areas Of the roof. Waterproofing integrity of lap Pass ASTM D1970 <br /> Underlayments can be required by local building Slip resistance Pass ASTM D1970 <br /> Thermal stability Pass ASTM D1204 <br /> codes, especially in northern climates when average ASTM D1970 <br /> January temperatures are 25' F (3.8° C). They Moisture vapor permeance Max.0.1 ASTM E96 <br /> provide protection from water migration caused UV exposure limit 60 days <br /> by ice damming. Service temperature -40°F to 200°F(-40°C to 93°c) <br /> Storage temperature,max Up to 104°F(40°C) <br /> Product characteristics ISO 1.95 SO 2.25 SO' <br /> We've got you covered Width,in(m) 36(0.9) 36(0.9) 44(1.1) <br /> With direct-to-deck application, Eaveguard®is Length,ft(m) 33(10) 65(19.8) 61(18.5) <br /> designed to offer protection in vulnerable areas of Gross coverage,ft'(ml 100(9.3) 195(18.1) 225(20.9) <br /> steep-slope roofs: Rolls per pallet 42 30 30 <br /> • At eaves, valleys and rakes Product approvals and certifications <br /> Meets performance criteria of ASTM D1970 <br /> • Roof-to-wall connections ICC-ESR-1930 <br /> • Flashing around chimneys and skylights ASTM E108/UL 790-Class A Fire Resistance <br /> • Roof vents and other penetrations Florida Building Code Approved Product#FL16724 <br /> • Full deck coverage Miami-Dade County Approved(NOA 16-0607.08) <br /> TDl Listed <br /> Learn more about Henry® roofing systems at 'avallableIn Canada only <br /> www.henry.com. <br /> Henry Building Envelope Systems® ' • • ' ' solutions <br /> Roofing Air Barrier 1 Waterproofing manage the flow of water, air,vapor and energy. <br /> productsupport@henry.com 1 1-800-486-1278 OD 2022 Henry Company All tights reserved. <br /> www.henry.com Printed in U.S.A 133.3US.E107(05122) <br />
The URL can be used to link to this page
Your browser does not support the video tag.