My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 112TH ST SW BLDG B SAGE APARTMENTS 2025-04-09
>
Address Records
>
112TH ST SW
>
1730
>
SAGE APARTMENTS
>
1730 112TH ST SW BLDG B SAGE APARTMENTS 2025-04-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2025 8:45:34 AM
Creation date
3/13/2025 2:56:55 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1730
Unit
BLDG B
Tenant Name
SAGE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Eaveguard°meets or exceeds requirements of <br /> ASTM D1970 as outlined below. <br /> Physical properties <br /> iMINOI� Surfacing Sand <br /> Henry® Eaveguard® provides Composition Modified-Asphalt Fiberglass <br /> Reinforced Membrane <br /> a secondary line of defense <br /> to keep water that can get Thickness,nominal 57 mils <br /> Performance properties Requirement Test method <br /> behind shingles from infiltrating - -- <br /> further to help ensure the Maximum load, MD/XD Min.25lbf/in-width ASTM D2523 <br /> ASTM D1970 <br /> longevity of your roof. Elongation at break,MD/XD Min.10% ASTM D2523 <br /> Modified-Asphalt Portion ASTM D1970 <br /> Tear resistance,MD/XD Min.20 Ibf ASTM D4073 <br /> ASTM D1970 <br /> Adhesion to plywood <br /> Why are self-adhered <br /> at 40°F Min.2Ibf/ft-width ASTM 903 <br /> at 75°F Min.12 1bf/ft-width ASTM D1970 <br /> Underlayments needed? <br /> Nail sealability Pass ASTM D1970 <br /> Sloped roofs are designed to shed water. ASTM D7349 <br /> Underlayments provide waterproofing protection Low temperature flexibility Pass ASTM D1970 <br /> allowing for proper water flow while protecting Waterproofing integrity after Pass ASTM D1970 <br /> low temperature flex <br /> vulnerable areas of the roof. Waterproofing Integrity of lap Pass ASTM D1970 <br /> Slip resistance Pass ASTM D1970 <br /> Underlayments can be required by local building Thermal stability Pass ASTM D1204 <br /> codes, especially in northern climates when average ASTM D1970 <br /> January temperatures are 25' F (3.8o C). They Moisture vapor permeance Max.0.1 ASTM E96 <br /> provide protection from water migration caused UV exposure limit 60 days <br /> by ice damming. Service temperature -40°F to 200°F(-40°C to 93°C) <br /> Storage temperature,max Up to 104°F(40°C) <br /> Product characteristics 1 SO 1.95 SO 2.25 SO' <br /> We've got you covered Width,in(m) 36(0.9) 36(0.9) 44(1.1) <br /> With direct-to-deck application, Eaveguard°is length,it(m) 33(10) 65(19.8) 61(16.5) <br /> Gross <br /> designed to offer protection in vulnerable areas of _coverage,it'(m� 100(s.3) 195(18.1) 30 <br /> (20.9) <br /> steep-slope roofs: Rolls per pallet 42 30 <br /> Product approvals and certifications <br /> •At eaves,valleys and rakes - - <br /> Meets performance criteria of ASTM D1970 <br /> • Roof-to-wall connections ICO-ESR-1930 <br /> • Flashing around chimneys and skylights ASTM E108/UI-790-Class.A Fire Resistance <br /> • Roof vents and other penetrations Florida Building code Approved Product 4FL16724 <br /> Miami-Dade County Approved(NOA 16-0607.08) <br /> • Full deck coverage <br /> TDl listed <br /> Learn more about Henry®roofing systems at available In Canada only <br /> www.henry.com. <br /> Henry + Building Envelope Systems® Aaboutother solutions ' <br /> t help <br /> • Roofing i Air Barrier I Waterproofing rnanage the flow of water, air,val)or and energy. <br /> productsupport@henry.com 1 1-800-486-1278 cc 2022 Henry Company All rights reserved. <br /> www.henry.com Printed in U.S.A 133.3US.E107(05122) <br />
The URL can be used to link to this page
Your browser does not support the video tag.