My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 112TH ST SW BLDG D SAGE APARTMENTS 2025-04-07
>
Address Records
>
112TH ST SW
>
1730
>
SAGE APARTMENTS
>
1730 112TH ST SW BLDG D SAGE APARTMENTS 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 11:59:39 AM
Creation date
3/13/2025 3:10:26 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1730
Unit
BLDG D
Tenant Name
SAGE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Eaveguard°meets or exceeds requirements of <br /> ASTM D197O as outlined below. <br /> Physical properties <br /> u11Nou Surfacing Sand <br /> Henry® Eaveguard® provides Composition Modified-Asphalt Fiberglass <br /> Reinforced Membrane <br /> a secondary line of defense <br /> tThickness,nominal 57 mils <br /> o keep water that can get <br /> Performance properties Requirement Test method <br /> behind shingles from infiltrating <br /> further to help ensure the Maximum load, MD/XD Min.25lbf/iin-width ASTM D2523 <br /> ASTM D1970 <br /> longevity of your roof. <br /> Elongation at break,MD/XD Min.10°k ASTM D2523 <br /> -Modified-Asphalt Portion ASTM D1970 <br /> Tear resistance,MD/XD Min.20 Ibf ASTM D4073 <br /> IN <br /> ASTM D1970 <br /> Adhesion to plywood <br /> Why are self-adheredat 40°F Min.2Ibf/ft-width ASTM 903 <br /> underlayments needed? at 75•F MIn.12 Ibf/ft-width ASTM D1970 <br /> Nail sealability Pass ASTM D1970 <br /> Sloped roofs are designed to shed water. I I ASTM D7349 <br /> Underlayments provide waterproofing protection Low temperature flexibility Pass ASTM D1970 <br /> allowing for proper water flow while protecting Waterproofing Integrity after Pass ASTM D1970 <br /> low temperature flex <br /> vulnerable areas of the roof. Waterproofing Integrity of lap Pass ASTM D1970 <br /> Slip resistance Pass ASTM D1970 <br /> Underlayments can be required by local building - <br /> Thermal stability Pass ASTM D1204 <br /> codes, especially in northern climates when average ASTM D1970 <br /> January temperatures are 250 F (3.8° C). They Moisture vapor permeance Max.0.1 ASTM E96 <br /> provide protection from water migration caused UV exposure limit 60days <br /> by ice damming. Service temperature -40•F to 200•F(-40°C to 93°C) <br /> Storage temperature,max Up to 104•F(40•C) <br /> Product characteristics ISO 1.95 SO 2.25 SO* <br /> We've got you covered Width,in(m) 36(0.9) 36(0.9) 44(1.1) <br /> With direct-to-deck application, Eaveguard°is Length,ft(m) 33(10) 65(19.8) 61(18.5) <br /> Gross coverage,ft2(mj 100(9.3) 195(18.1) 225(20.9) <br /> designed to offer protection in vulnerable areas of - - -- - - - <br /> steep-slope roofs: Rolls per pallet 42 30 30 <br /> Product approvals and certifications <br /> •At eaves,valleys and rakes <br /> Meets performance criteria of ASTM D1970 <br /> • Roof-to-wall connections <br /> ICC-ESR-1930 <br /> • Flashing around chimneys and skylights ASTM E1oe/UL 790-Class A Fire Resistance <br /> • Roof vents and other penetrations Florida Building code Approved Product aFL16724 <br /> Miami-Dade County Approved(NOA 16-0607.08) <br /> • Full deck coverage - <br />� TDi Listed <br /> i <br /> Learn more about Henry® roofing systems at *available In Canada only <br /> www.henry.com. <br /> HenryI Building Envelope Systems® ' ' ' ' <br /> • Roofing I Air Barrier I Waterproofing <br /> productsupportMenry.eom 1 1-800-486-1278 (c 2022 Henry Company Au rights reserved. <br /> www.henry.com Printed in U.S.A 133.3US.E107(05/22) <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.