Laserfiche WebLink
Eaveguarda meets or exceeds requirements of <br /> ASTM D1970 as outlined below. <br /> Physical properties <br /> MINOti Surfacing Sand <br /> 1JM�RIAYMENt <br /> Henry® Eaveguard® provides Composition Modified Asphalt Fiberglass <br /> Reinforced Membrane <br /> a secondary line of defense <br /> 10 Thickness,nominal 57 mils _ <br /> to keep water that can get <br /> Performance properties Requirement Test method <br /> behind shingles from infiltrating <br /> Maximum load, MD/XD Min.251bfln width ASTM D2523 <br /> further to help ensure the <br /> ASTM D19701970 <br /> longevity of your roof. Elongation at break,MD/XD Min,10% ASTM D2523 <br /> - - — . <br /> -Modified-Asphalt Portion ASTM D1970 <br /> Tear resistance,MD/XD Min.20 Ibf ASTM D4073 <br /> ASTM D1970 <br /> Adhesion to plywood <br /> Why are self-adhered at 40'F Min.2lbf/ft-width ASTM 903 <br /> (� <br /> at 75'F Min.12 Ibf/ft-width ASTM D1970 <br /> underlayments needed? Nail sealability Pass ASTM D1970 <br /> ASTM D7349 <br /> Sloped roofs are designed to shed water. - <br /> Low temperature flexibility Pass ASTM D1970 <br /> Underlayments provide waterproofing protection Waterproofing integrity after Pass ASTM D1970 <br /> allowing for proper water flow while protecting low temperature flex <br /> vulnerable areas of the roof. waterproofing integrity of lap Pass ASTM D1970 <br /> Slip resistance Pass ASTM D1970 <br /> Underlayments can be required by local building Thermal stability Pass ASTM D1204 <br /> codes, especially in northern climates when average ASTM D1970 <br /> January temperatures are 250 F (3.8° C). They Moisture vapor permeance Max.0.1 ASTME96 <br /> provide protection from water migration caused uv exposure limit 60 days <br /> by ice damming. service temperature -40'F to zoo°F(-40'C to 93'c) <br /> Storage temperature,max Up to 104'F(40'C) <br /> ------------ ------------------------------------- <br /> Product characteristics 1 SO 1.95 SO 2.25 SO' <br /> We've got you covered <br /> Width,in(m) 36(0.9) 36(0.9) 44(1.1) <br /> Length,It(m) 33(10) 65(19.8) 61(18.5) <br /> With direct-to-deck application, Eaveguard°is <br /> Gross coverage,ftz(mg 100(9.3) 195(18.1) 225(20.9) <br /> designed to offer protection in vulnerable areas of <br /> Rolls per pallet 42 30 30 <br /> steep-slope roofs: - <br /> Product approvals and certifications <br /> • At eaves, valleys and rakes - e - <br /> Meets performance criteria of ASTM D1970 <br /> • Roof-to-wall connections ICO-ESR-1930 <br /> • Flashing around chimneys and skylights ASTM E108/UL 790-Class.A Fire Resistance <br /> Florida Building Code Approved Product#IFL16724 <br /> • Roof vents and other penetrations - - <br /> Miami-Dade County Approved(NOA 16-0607.08) <br /> • Full deck coverage TDI Listed <br /> Learn more about Hene roofing systems at *available In Canada only <br /> www.henry.com. <br /> Henry• Building Envelope systems® Ask us to(lay ab0LIt other Henry solutions that liell) <br /> Roofing I Air Barrier I Waterproofing nianage the flow of water, air,val)oi and energy. <br /> productsupport@henry.com 1 1-800-486-1278 OD 2022 Henry company All rights reserved. <br /> www.henry.com Printed in U.S.A 133.3US.E707(05/22) <br />