My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 112TH ST SW BLDG G SAGE APARTMENTS 2025-04-07
>
Address Records
>
112TH ST SW
>
1730
>
SAGE APARTMENTS
>
1730 112TH ST SW BLDG G SAGE APARTMENTS 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:12:11 PM
Creation date
3/13/2025 3:33:14 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1730
Unit
BLDG G
Tenant Name
SAGE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Eaveguard°meets or exceeds requirements of <br /> ASTM D1970 as outlined below. <br /> Physical properties <br /> �HtiVOfs Surfacing Sand <br /> Henry® Eaveguard® provides Composition Modified-Asphalt Fiberglass <br /> 57 mils <br /> Membrane <br /> a secondary line of defense <br /> Thickness,nominal mils <br /> to keep water that can get <br /> Performance properties Requirement Test method <br /> behind shingles from infiltrating <br /> ASTM D2523 <br /> further to help ensure the Maximum load, MD/XD Min.251bfln-width ASTM D1970 <br /> longevity of your roof. Elongation at break,MDAD Min.10% ASTM D2523 <br /> Modified-Asphalt Portion ASTM D1970 <br /> - - - -- <br /> Tear resistance MD/XD Min.201bf ASTM D4073 <br /> -10, rpj AST M D1970 <br /> r�•sarr �� <br /> Adhesion to plywood <br /> Why are self-adhered at 40'F Min.2lbf/ft-width ASTM 903 <br /> is at 75'F Min.12 Ibf/ft-width ASTM D1970 <br /> underlayments needed? <br /> Nail sealability, Pass ASTM D1970 <br /> ASTM D7349 <br /> Sloped roofs are designed to shed water. - - <br /> Low temperature flexibility Pass ASTM D1970 <br /> Underlayments provide waterproofing protection - - <br /> Waterproofing integrity after Pass ASTM D1970 <br /> allowing for proper water flow while protecting low temperature flex <br /> vulnerable areas of the roof. waterproofing Integrity of lap Pass ASTM D1970 <br /> Slip resistance Pass ASTM D1970 <br /> Underlayments can be required by local building Thermal stability Pass ASTM D1204 <br /> codes, especially in northern climates when average <br /> ASTM D1970 <br /> January temperatures are 25' F (3.8' C). They Moisture vapor permeance Max.0.1 ASTME96 <br /> provide protection from water migration caused UV exposure limit 60 days <br /> by ice damming. Service temperature -40'F to 200'F(-40'C to 93'C) <br /> Storage temperature,Max Up to 104'F(40'C) <br /> ' Product characteristics 1 SO 1.95 SO 2.25 SO* <br /> We've got you covered width,In(m) 36(0.9) 36(0.9) 44(1.1) <br /> Length,It(m) 33(10) 65(19.8) 61(18.5) <br /> With direct-to-deck application, Eaveguard®is - <br /> Gross coverage,ft2(m� 100(9.3) 195(18.1) 225(20.9) <br /> designed to offer protection in vulnerable areas of - <br /> Rolls per pallet 42 30 30 <br /> steep-slope roofs: - <br /> Product approvals and certifications <br /> • At eaves, valleys and rakes <br /> Meets performance criteria of ASTM D1970 <br /> • Roof-to-wall connections ICC-ESR-1930 <br /> • Flashing around chimneys and skylights ASTM E108/UL 790-Class.A Fire Resistance <br /> • Roof vents and other penetrations Florida Building code Approved Product fIFL16724 <br /> Miami-Dade County Approved(NOA 16-0607.08) <br /> • Full deck coverage TDI Listed <br /> Learn more about Henry® roofing systems at avallableIn Canada only <br /> www.henry.com. <br /> Henry ` Building Envelope systems® <br /> • Roofing I Air Barrier I Waterproofing <br /> productsupport@henry.com 1 1-800-486-1278 2022 Henry Company All rights reserved. <br /> www.henry.com Printed in U.S.A 133.3US.E107(05/22) <br />
The URL can be used to link to this page
Your browser does not support the video tag.