My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 112TH ST SW CLUBHOUSE SAGE APARTMENTS 2025-04-07
>
Address Records
>
112TH ST SW
>
1730
>
SAGE APARTMENTS
>
1730 112TH ST SW CLUBHOUSE SAGE APARTMENTS 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 1:29:21 PM
Creation date
3/13/2025 3:48:46 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SW
Street Number
1730
Unit
CLUBHOUSE
Tenant Name
SAGE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Eaveguard°meets or exceeds requirements of <br /> ASTM D197O as outlined below. <br /> Physical properties <br /> Imp <br /> Surfacing Sand <br /> Henry® Eaveguard® providesComposition Modified-Asphalt Fiberglass <br /> Reinforced Membrane <br /> a secondary line of defense <br /> Thickness,nominal 57 mils <br /> to keep water that can get <br /> behind shingles from infiltrating Performancepropertles Requirement Test method <br /> further to help ensure the Maximum load, MD/XD Min.25lbf/in-width ASTM D2523 <br /> ASTM D1970 <br /> longevity of your roof. <br /> Elongation at break,MD/XD Min.10% ASTM D2523 <br /> ' -Modified-Asphalt Portion ASTM D1970 <br /> Tear resistance,MD/XD Min.20 Ibf ASTM D4073 <br /> ASTM D1970 <br /> Adhesion to plywood <br /> Why are self-adheredat 40°F Mln.2 Ibflft-width ASTM 903 <br /> Is <br /> UnderlaymentS heeded? at 75°F Min.12 Ibf/ft-width ASTM D1970 <br /> Nail sealability Pass ASTM D1970 <br /> Sloped roofs are designed to shed water. I ASTM D7349 <br /> Underlayments provide waterproofing protection Low temperature flexibility Pass ASTM D1970 <br /> allowing for proper water flow while protecting Waterproofing Integrity after Pass ASTM D1970 <br /> low temperature flex <br /> vulnerable areas of the roof. Waterproofing Integrity of lap Pass ASTM 131970 <br /> Slip resistance Pass ASTM D1970 <br /> Underlayments can be required by local building Thermal Stability Pass ASTM D1204 <br /> codes, especially in northern climates when average ASTM D1970 <br /> January temperatures are 25° F (3.8° C). They Moisture vapor permeance Max.0.1 ASTM E96 <br /> provide protection from water migration caused UV exposure limit 60 days <br /> by ice damming. Service temperature -40°F to 200°F(40°C to 93°C) <br /> Storage temperature,max Up to 104°F(40°C) <br /> Product characteristics 1 SO 1.95 SO 2.25 SO' <br /> We've got you covered Width,in(m) 36(0.9) 36(0.9) 44(1.1) <br /> With direct-to-deck application, Eaveguard° is Length,n(m) 33(10) 65(19.8) 61(18.5) <br /> designed to offer protection in vulnerable areas of cress coverage,ft'(m� 100(9.3) 195(18.1) 225(20.9) <br /> _ - <br /> steep-slope roofs: Roils per palletllet 42 30 30 <br /> Product approvals and certifications <br /> • At eaves, valleys and rakes - - - <br /> Meets performance criteria of ASTM D1970 <br /> • Roof-to-wall connections <br /> ICC-ESR-1930 <br /> • Flashing around chimneys and skylights ASTM Ell 08/UL 790-Class.A Fire Resistance <br /> • Roof vents and other penetrations Florida Building Code Approved Product#FL16724 <br /> Miami-Dade County Approved(NOA 16-0607.08) <br /> • Full deck coverage <br /> TDI Listed <br /> Learn more about Henry® roofing systems at *available In Canada only <br /> www.henry.com. <br /> it <br /> that liell) <br /> Building Envelope Systems® Ask Lis todayabout ' ' ' <br /> Henry. nsffier( Roofing I Air Barrier I Waterproofing <br /> productsupport@henry,com 1 1-800-486-1278 r0 2022 Henry company All rights reserved. <br /> www.henry.com Printed in U.S.A 133.3US.E107(05/22) <br />
The URL can be used to link to this page
Your browser does not support the video tag.