Laserfiche WebLink
MEMBER REPORT <br /> PASSED <br /> Floor, UB-02 <br /> 1 piece(s)5 1/2"x 16 1/2"24F-V4 OF Glulam <br /> Overall Length:21' <br /> 0 ,0 <br /> �I..,.. 21' <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(lbs) 6094 @ 4" 15194(4.25") Passed(4000) -- 1.0 D+0.75 L+0.75 S(All Spans) Member Type:Flush Beam <br /> Building Use:Residential <br /> Shear(lbs) 5524 @ 1'10" 18437 Passed(300/0) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Building Code:IBC 2018 <br /> Pos Moment(Ft-lbs) 44158 @ 10'6" 55387 Passed(80%) 1.15 1.0 D+0.75 L+0.75 S(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.411 @ 10'6" 0.508 Passed(L/594) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> Total Load Defl.(in) 0.778©10'6" 1.017 Passed(L/314) -- 1.0 D+0.75 L+0.75 S(All Spans) <br /> • Deflection criteria:LL(L/480)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor, <br /> •Critical positive moment adjusted by a volume factor of 0.96 that was calculated using length L=20'4". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(lbs) <br /> Supports Total Available Required Dead Floor Live Snow Total Accessories <br /> 1-Column-DF 5.50" 4.25" 1.70" 2958 1680 2544 7182 1 1/4"Rim Board <br /> 2-Beam-GLB 5.50" 5.50" 1.71" 2960 1680 2545 7185 Blocking <br /> •Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 20'11"o/c <br /> Bottom Edge(Lu) 20'11"o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead '' Floor Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (1.15) Comments <br /> 0-Self Weight(PLF) 1 1/4"to 21' N/A 22.1 -- -- <br /> 1-Uniform(PSF) 0 to 21'(Front) 1' 12.0 40.0 - Floor <br /> 2-Uniform(PSF) 0 to 21'(Front) 2' 12.0 60.0 - Low Roof <br /> 3-Uniform(PLF) 0 to 21'(Front) N/A 90.0 - - Wall <br /> 4-Uniform(PSF) 0 to 21'(Front) 2' 12.0 - 25.0 Roof <br /> 5-Point(lb) 10'6"(Front) N/A 2307 - 4039 Linked from:RB-al, <br /> Support 2 <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator lob Notes 5/5/2022 11:30:59 PM UTC <br /> Kelsi Bonner 4 BTL Engineering ForteWEB v3.2,Engine:V8.2.0.17,Data: V8.1.0.16 <br /> (931)581-9272 <br /> kelsi.bonner@btleng.net Weyerhaeuser File Name: Peterson Garage-Everett <br /> U 2.6 Page 3/8 <br />