Laserfiche WebLink
Lateral Analysis /BC 2018 <br /> UPSTATE JOB#: 1587 <br /> Description: NEW GARAGE <br /> Engineer: JBG <br /> Governing Code: 2018 International Building Code all references in right margin are 2018 <br /> IBC unless specifically noted otherwise. <br /> 1603.1 General Design Criteria <br /> Roof Walls Floors Snow Partitions <br /> Live Load (psf) 25 40 25 <br /> Dead Load (psf) 15 10 10 0 10 <br /> 1603.1.4 Wind Design Criteria <br /> 1. Basic/ASD Wind Speed VNasd 110/85 mph F 1609.3(1) <br /> 2. Risk Category II 1.00 ASCE 7T 1.5-1 <br /> 3. Wind Exposure Category 'B" 1609.4 <br /> 4. Internal Pressure Coefficient +/-0. 55 ASCE 7 F 26.13-1 <br /> 5. Components and Cladding design pressure +/- 16 psf ASCE7 30.2.2 <br /> 1603.1.5 Earthquake Design Data <br /> 1. Risk Category II ASCE 7 T 1.5-1 <br /> 2. Seismic Importance Factor le 1.00 ASCE 7 T 1.5-2 <br /> 3. Short Period Acceleration SS 1.31 USGS Seismic Design Map Online <br /> 1-Second Accelleration Si 0.46 USGS Seismic Design Map Online <br /> 4. Site Class D ASCE 7T20.3-1 <br /> 5. Spectral response coefficient SDS 1.04 EQ 16-38 <br /> Spectral response coefficient SD1 N/A EQ 16-39 <br /> 6. Seismic Design Category D T1613.2.3(1)and(2) <br /> 7. Seis. Force Resisting System A.15. ASCE 7T 12.2--1 <br /> 8. Design Base Shear 1931 lbs See Page 3.0 <br /> 9. Seismic Response Coefficient Cs 0.16 ASCE7EQ 128-2 <br /> 10. Response Modification Factor R 6.5 ASCE 7T 122-1 <br /> 11. Analysis Procedure Equivalent Lateral Force ASCE 7 128 <br /> Table of Contents <br /> 0.0 General Lateral Design Criteria <br /> 1.0 Determination of Wind Forces <br /> 2.0 Determination of Seismic Forces <br /> 3.0 Allowable Stress Design Loads <br /> 4.0 Shear walls in the Front to Rear Direction <br /> 5.0 Shear walls in the Side to Side Direction <br /> 6.0 Shear flow calculations <br /> 7.0 Appendix <br /> Version 7.0 Pg 0.1 <br />