Laserfiche WebLink
FIRE SYSTEM ACCESSORY <br /> Model 5495 <br /> ItSILENT Distributed Power Module <br /> ik KNIGHT <br /> In an emergency, <br /> by Honeywell you need maximum power <br /> The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply <br /> available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for <br /> appliances from System Sensoro,Gentex®,AMSECO®, Wheelock and Faraday—what you need to drive power- <br /> hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years <br /> ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive <br /> linear mode power supplies.And,ADA retrofits are easier and less expensive with the 5495 because it <br /> integrates into current systems without the costly investment in new components. <br /> For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent <br /> Knight today for more information at 1-800-328-0103. <br /> Model 5495 to non-essential high-current <br /> Distributed Power Module accessories like magnetic door <br /> holders <br /> The 5495 is a 6 amp notification power • Built-in synchronization for <br /> expander that provides its own AC appliances from System <br /> power connection, battery charging Sensor®,Gentex®,AMSECO®, <br /> circuit, and backup battery for use with Wheelock and Faraday <br /> fire and security controls such as the <br /> Silent Knight Model 5208 Fire Control • Stand alone operation <br /> /Communicator.The 5495 is the cost- • Lightweight design adds to ease of <br /> effective solution for powering g installation and reduces shipping <br /> notification appliances required by the costs <br /> Americans with Disabilities Act(ADA). • Operates with most polarized, UL <br /> The 5495 has built-in ANSI cadence Listed notification devices <br /> pattern,which can upgrade older <br /> control panels that lack cadence • <br /> ANSI Cadence pattern output <br /> capability. capability built-in <br /> Features Connection to Local Fire Control <br /> • UL Listed for 6 amps of notification The 5495 may be connected to a local Model 5495 <br /> fire control which utilizes Class A or <br /> power Class B type notification circuits Distributed Power Module <br /> • Power supply's advanced switch operating between 9 and 32 VDC.The <br /> mode design reduces damaging control panel's notification circuit is Approvals <br /> heat and manages power up to 50% connected to one of the inputs on the • UL Listed <br /> more efficiently than other systems 5495.The control panel's notification • MEA 429-92-E Vol XII <br /> • Dip switches allow for easy circuit end-of-line resistor is also • CSFM 7300-0559:123 <br /> reconfiguration connected across two terminals on the <br /> • <br /> • 24 VDC filtered output voltage 5495, which provides supervision NFPA 72 <br /> • Four power limited notification between the 5495 and the fire control <br /> outputs; 2 Class A or 4 Class B, or 1 panel. Polarized audible and/or visual <br /> Class A and 2 Class B notification devices are then connected <br /> • Additional continuous auxiliary to the 5495 signal circuits using the <br /> output 4.7kc2 end-of-line resistors provided. <br /> Since the 5495 draws very little power <br /> • 3 amps per output circuit from the control, it is possible to <br /> • 2 inputs;2 Class B or 2 Class A connect one 5495 to each notification <br /> • Ground fault detector/indicator circuit on the control panel and still <br /> • Independent trouble relay provide full supervision of the <br /> • AC loss delay option shuts off power notification circuits all the way back to <br /> the control panel. <br />